PRODUCTS CENTER


● Application: Prepaid & Postpaid (See Acrel Prepaid Solution) ● Monitoring: Up to 36 Circuits 1-phase or 12 Circuits 3-phase or Mixed ● Measurement: 1-phase&3-phase kWh (Class 0.5S), kVarh, Active Power, Reactive Power, Current, Voltage and etc ● Rated Voltage: 3x220/380V (50Hz) ● Rated Current: 80A AC (direct connection); 3x1(6)A AC (via CTs) ● Communication (Main Body): RS485 (MODBUS-RTU); Ethernet; Infrared ● Communication (Expanded): 4G; WiFi; LoRa ● Remote Control: DO&DI ● Installtion: 35mm DIN Rail ● Power Supply: 3*220/380V or 220V AC ● Standard&Certificate: CE

● Measures 4 channels of 3 phase circuits ● Measures 3 phase power, total power (active, reactive, apparent), U, I, P, Q, S, PF, F, zero sequence current, voltage/current phase angle, voltage/current degree of unbalance, etc. ● Communication: RS485(Modbus-RTU), LoRa ● Harmonic on 2nd-31st ● Multi tariff: 4 time zones 14Periods rate setting; ● Maximum Current, maximum power demand and real time Current, real time power demand; ● Record of voltage, current and power extreme of current month and last month; ● 200 event records, record the action of DIDO; ● Support over-voltage, over-current, phase failure, DI linkage and other alarm output; ● Accuracy: Class 1 ● 12 channel Switching inputs+4 channel Switching outputs; ● 12 channel external NTC temperature +4 channel residual current measurement (leakage current); ● Rated voltage: 3×220/380V ● Rated current: 5A( secondary transforming), 100A, 400A, 600A.

● Measures 4 channels of 3 phase circuits ● Measures 3 phase power, total power (active, reactive, apparent), U, I, P, Q, S, PF, F, zero sequence current, voltage/current phase angle, voltage/current degree of unbalance, etc. ● Communication: RS485(Modbus-RTU) ● Harmonic on 2nd-31st ● Multi tariff: 4 time zones 14Periods rate setting; ● Maximum Current, maximum power demand and real time Current, real time power demand; ● Record of voltage, current and power extreme of current month and last month; ● 200 event records, record the action of DIDO; ● Support over-voltage, over-current, phase failure, DI linkage and other alarm output; ● Accuracy: Class 1 ● 12 channel Switching inputs+4 channel Switching outputs; ● 12 channel external NTC temperature +4 channel residual current measurement (leakage current); ● Rated voltage: 3×220/380V ● Rated current: 5A( secondary transforming), 100A, 400A, 600A.

● Measures 4 channels of 3 phase circuits ● Measures 3 phase power, total power (active, reactive, apparent), U, I, P, Q, S, PF, F, zero sequence current, voltage/current phase angle, voltage/current degree of unbalance, etc. ● Communication: RS485(Modbus-RTU) ● Harmonic on 2nd-31st ● Multi tariff: 4 time zones 14Periods rate setting; ● Maximum Current, maximum power demand and real time Current, real time power demand; ● Record of voltage, current and power extreme of current month and last month; ● 200 event records, record the action of DIDO; ● Support over-voltage, over-current, phase failure, DI linkage and other alarm output; ● Accuracy: Class 1 ● 12 channel Switching inputs+4 channel Switching outputs; ● 12 bits section LCD display, background light ● 12 channel external NTC temperature +4 channel residual current measurement (leakage current); ● Rated voltage: 3×220/380V ● Rated current: 5A( secondary transforming), 100A, 400A, 600A.

< 1...616263...68 >