PRODUCTS CENTER
● Measures active kWh (positive and negative), Reactive kWh (positive and negative), U, I, P, Q, S, PF, F, etc. ● Communication: RS485(Modbus-RTU), link to IOT Platform ● Harmonic on 2nd-31st ● Multi tariff ● Max demand and and occurrence time ● Frozen data on last 48 months, last 90 days ● Accuracy:Class 0.5S ● Active pulse output ● 12 bits section LCD display, background light ● 3 keys to communication and set parameters ● Rated voltage: 3×100V, 3×380V, 3×57.7/100V, 3×230/400V (withstand 120% load) ● Rated current: 3×1(6)A, 3×10(80)A (withstand 120% load) ● Standard&Certificate: UL; CE; IEC
● Primary current is connected in through perforation. Easy installation, high safety. ● With Hall sensor, the max isolation measuring current 20A ● Voltage measurement range for Bus bar is up to DC1.5kV ● LED display, fit for checking and testing operation in wide-temperature or outside environment. ● With the function of inner temperature measurement for real-time measurement of the inner temperature of combiner box ● With RS485 Modbus RTU ● More options of power supply ● Compatible with din rail installation and baseboard fixation installation, small dimension saving more box space. ● Photovoltaic cell open circuit alarm to cooperate with group string voltage and judge Comprehensively ● With 3-channel switching state monitoring to collect output idle contact information of DC breaker 、lightning protector, etc. ● Option RS485 port, Modbus-RTU protocol; programmable slave address, baud rate, data format ● English LCD display,convenient to set parameters and check the data ● Mounted: Din rail 35mm ● Standard & Certificate: CE; IEC;
● Measurement: kWh, U, I, P, Q, S, etc. ● Measures 2 channels of DC energy(optional) ● Measures bidirectional DC energy ● Communication: RS485(Modbus-RTU),2 channels of RS485(optional) ● Communication protocol: Modbus-RTU, DL/T 645-2007 ● Built-in Bipolar Power Source: Power Supply for Hall Effect CT (DC -12V ~ DC +12V) ● Voltage input range: DC0-1000V ● Input signal: Shunt:0-75mV;Hall sensor:0-20mA, 4-20mA, 0-5V, 0-10V and so on. ● 2DI/2DO ● Power supply: AC/DC 85-265V or DC24V(±10%) or DC48V(±10%) ● Accuracy: 1 or 0.5 (connected via shunt)(optional) ● Switch output: 2 Relay outputs, 2A/30VDC or 2A/250VAC ● Switch input: 2 dry contact inputs ● Pulse output: A second pulse output, an energy pulse output ● Display: 8 digits display U, I, P, Q, kWh and other energy consumption ● Average barrier-free working hours: ≥50000h ● Mounted: Din rail 35mm ● Standard & Certificate: CE; IEC; UL
● Application: Prepaid & Postpaid (See Acrel Prepaid Solution) ● Monitoring: Up to 36 Circuits 1-phase or 12 Circuits 3-phase or Mixed ● Measurement: 1-phase&3-phase kWh (Class 0.5S), kVarh, Active Power, Reactive Power, Current, Voltage and etc ● Rated Voltage: 3x220/380V (50Hz) ● Rated Current: 80A AC (direct connection); 3x1(6)A AC (via CTs) ● Communication (Main Body): RS485 (MODBUS-RTU); Ethernet; Infrared ● Communication (Expanded): 4G; WiFi; LoRa ● Remote Control: DO&DI ● Installtion: 35mm DIN Rail ● Power Supply: 3*220/380V or 220V AC ● Standard&Certificate: CE