PRODUCTS CENTER


● Measures 4 channels of 3 phase circuits ● Measures 3 phase power, total power (active, reactive, apparent), U, I, P, Q, S, PF, F, zero sequence current, voltage/current phase angle, voltage/current degree of unbalance, etc. ● Communication: RS485(Modbus-RTU) ● Harmonic on 2nd-31st ● Multi tariff: 4 time zones 14Periods rate setting; ● Maximum Current, maximum power demand and real time Current, real time power demand; ● Record of voltage, current and power extreme of current month and last month; ● 200 event records, record the action of DIDO; ● Support over-voltage, over-current, phase failure, DI linkage and other alarm output; ● Accuracy: Class 1 ● 12 channel Switching inputs+4 channel Switching outputs; ● 12 channel external NTC temperature +4 channel residual current measurement (leakage current); ● Rated voltage: 3×220/380V ● Rated current: 5A( secondary transforming), 100A, 400A, 600A.

● Measures 4 channels of 3 phase circuits ● Measures 3 phase power, total power (active, reactive, apparent), U, I, P, Q, S, PF, F, zero sequence current, voltage/current phase angle, voltage/current degree of unbalance, etc. ● Communication: RS485(Modbus-RTU) ● Harmonic on 2nd-31st ● Multi tariff: 4 time zones 14Periods rate setting; ● Maximum Current, maximum power demand and real time Current, real time power demand; ● Record of voltage, current and power extreme of current month and last month; ● 200 event records, record the action of DIDO; ● Support over-voltage, over-current, phase failure, DI linkage and other alarm output; ● Accuracy: Class 1 ● 12 channel Switching inputs+4 channel Switching outputs; ● 12 bits section LCD display, background light ● 12 channel external NTC temperature +4 channel residual current measurement (leakage current); ● Rated voltage: 3×220/380V ● Rated current: 5A( secondary transforming), 100A, 400A, 600A.

● Measurement: kWh, U, I, P, Q, S, etc. ● Can supply power ±12V to hall sensor ● Measures bidirectional DC energy ● Communication: RS485(Modbus-RTU)、Half duplex、Photoelectric isolation、Modbus-RTU / DL/T645-07、 Band:1200/2400/4800/9600、Infrared:1200 ● Communication protocol: Modbus-RTU, DL/T 645-07 ● Built-in Bipolar Power Source: Power Supply for Hall Effect CT (DC -12V ~ DC +12V) ● Voltage input range: DC0-1000V ● Input signal: Shunt:0-75mV;Hall sensor:0-20mA, 0-5V, etc. ● 4DI/2DO ● Power supply: AC/DC 85-265V or DC20-60VDC, or 100-350VDC ● Accuracy: 0.5 ● Current Range: 0-2500A(External Shunt or Hall Current Sensor, the range can be set) ● Multiple Rate: Four time zones、two time table、fourteen time points、four multiple rates. (PZ72L-DE support only) ● Historical data statistics: Last 12 months of historical electricity(multiple rate electricity). (PZ72L-DE support only) ● Display: 8 digits display U, I, P, Q, kWh and other energy consumption ● Overload: It can work at normal status at 1.2 times of full load, and can continued work 1 second at 2 times of full load. ● Mounted: Din rail 35mm ● Standard & Certificate: CE; IEC;

● Measurement: kWh, U, I, P, Q, S, etc. ● Can supply power ±12V to hall sensor ● Measures bidirectional DC energy ● Communication: RS485(Modbus-RTU)、Half duplex、Photoelectric isolation、Modbus-RTU / DL/T645-07、 Band:1200/2400/4800/9600、Infrared:1200 ● Communication protocol: Modbus-RTU, DL/T 645-07 ● Built-in Bipolar Power Source: Power Supply for Hall Effect CT (DC -12V ~ DC +12V) ● Voltage input range: DC0-1000V ● Input signal: Shunt:0-75mV;Hall sensor:0-20mA, 0-5V, etc. ● 4DI/2DO ● Power supply: AC/DC 85-265V or DC20-60VDC, or 100-350VDC ● Accuracy: 0.5 ● Current Range: 0-2500A(External Shunt or Hall Current Sensor, the range can be set) ● Multiple Rate: Four time zones、two time table、fourteen time points、four multiple rates. (PZ72L-DE support only) ● Historical data statistics: Last 12 months of historical electricity(multiple rate electricity). (PZ72L-DE support only) ● Display: 8 digits display U, I, P, Q, kWh and other energy consumption ● Overload: It can work at normal status at 1.2 times of full load, and can continued work 1 second at 2 times of full load. ● Mounted: Din rail 35mm ● Standard & Certificate: CE; IEC;