PRODUCTS CENTER


Belize Acrel ADL400N-CT/D36 CE MID Approved Digital 300A Three Phase Energy Meter for EV Charging Piles IOT Platform Energy Consumption Monitoring

● 3 phase 4 wire, 3 phase 3 wire, single phase 3 wire ● Rated voltage: 3×230/400V、3×277/480V; ● Rated current: 3×80A, 3×120A, 3×200A, 3×300A ● Overload: 1.2 times rating (continuous)                      2 times the rating for 1 second ● Accuracy: 0.5 ● Accuracy of active energy:Class B (split current transformer) /Class C (closed current transformer)  ● Communication: RS485(Modbus-RTU) ● kWh  (positive and negative) ● kVarh (positive and negative) ● U, I, P, Q, S, PF, Hz, etc. ● Communication, transformation ratio and other parameters can be programmable by the key ● LCD dispaly: Segmented LCD display ● Active pulse output ● LED alarm: Operation instructions ● Grid frequency: 45~65Hz, error ±0.5% ● Standard&Certificate: MID; CE;

Product Description

 

 

Overview

     

 

        ADL series DIN-rail mounted multifunctional electric energy meter is an intelligent instrument mainly designed for new energy power generation systems such as photovoltaic grid-connected system, micro inverter system, energy storage system, AC coupling system, etc.

        The product has the advantages of high precision, small volume, high respondent speed and convenient installation.

        The product has the features of sampling, metering and monitoring power parameters, communicating with an inverter or an energy management system (EMS), realizing the functions of preventing reverse flow, regulating power generation, charging and discharging batteries according to real-time power and accumulated electric energy, and realizing bidirectional metering and household distributed photovoltaic energy management. 

 

 

 

Coding Rule

 

 

 

 

Dispaly

 

 

 

 

Application

 

 

Installed in charging piles

 

 

 

Used as a general 3 phase electricity meters

 

 

 

Network

 

 

 

 

 

Function

 

● 3 phase 4 wire, 3 phase 3 wire, single phase 3 wire

● Rated voltage: 3×230/400V、3×277/480V;

● Rated current: 3×80A, 3×120A, 3×200A, 3×300A 

● Overload: 1.2 times rating (continuous) 

                    2 times the rating for 1 second

● Accuracy: 0.5

● Accuracy of active energy:Class B (split current transformer) /Class C (closed current transformer) 

● Communication: RS485(Modbus-RTU)

Electricity Data Measurement

● kWh  (positive and negative)

● kVarh (positive and negative)

● U, I, P, Q, S, PF, Hz, etc.

● Communication, transformation ratio and other parameters can be programmable by the key

● LCD dispaly: Segmented LCD display

● Active pulse output

● LED alarm: Operation instructions

● Grid frequency: 45~65Hz, error ±0.5%

● Standard&Certificate: MID; CE;

● Power frequency withstand voltage: Between communication and signal input, AC4kV 1min

● Insulation resistance: Input and output terminals to casing >100MΩ

● Mounted: DIN 35mm

● Baud rate: Support 1200bps-38400bps

● Operating temperature: -40℃~+70℃

● Storage temperature: -40℃~+70℃

● Relative humidity: ≤95℅ (without condensation)

 

       

 

 

 

Dimension

 

 

 

 

 

Wiring

 

 

Figure 3 ADL200N-CT

 

 

Figure 4 ADL400N-CT Three-phase Four-wire Connection Through Current Transformer

 

 

 

 

 

Installation