PRODUCTS CENTER


Denmark ADW300-4GHW CE IEC Approved Wireless 4G Digital 3 Phase Energy Meter For IOT Platform Energy Consumption Monitoring

● Measures active kWh (positive and negative), Reactive kWh (positive and negative), U, I, P, Q, S, PF, F, etc. ● Communication: 4G, WiFi, LoRa, LoRaWAN, RS485(Modbus-RTU) ● Harmonic on 2nd-31st ● 4DI+2DO ● Measure 1 way of residual current ● Monitor 4 cables' temperature ● Power failure alarm, 2DI/2DO ● Multi tariff ● Max demand and and occurrence time ● Frozen data on last 48 months, last 90 days ● Accuracy:Class 0.5 ● Active pulse output ● 12 bits section LCD display, background light ● 3 keys to communication and set parameters ● Rated voltage: 3×57.7/100V,3×220/380V,3×380/660V,3×100V, 3×380V,3×660V ● Rated current: 3×1(6)A ● Standard&Certificate: CE; IEC

Product Description

 

 

Overview

     

        ADW300 wireless energy meters have multiple built-in communication modules designed for diffent situation when paired with IoT energy management system or other demand for remote connection. Meanwhile, ADW300 can provide various extration function module and various electrical parameters measurement to meet diffent requests from the customers. Also, as the prove for quality, ADW300 is strictly compliant of the standard of IEC 62052-11; IEC62053-22; LVD. Certificates are shown below.

 

 

 

Coding Rule

 

 

 

 

Dispaly

 

 

 

 

Function

 

Communication Function

●  WiFi

●  4G

●  Lora

●  Lorawan

●  NB-IOT

●  RS485(Modbus-RTU)

It can work with IOT Platform

Electricity Data Measurement

● kWh  (positive and negative)

● kVarh (positive and negative)

● U, I, P, Q, S, PF, Hz, etc.

● Harmonic (THDv, 2-31st)

● 3-phase current & voltage imbalance

● Multi tariff

● Max demand, etc.

● 12 months' historical data

● 2 DO Digital Output

● 4 DI Digital Input

● Accuracy:Class 0.5S

● Measures temperature of A/B/C/N

● Measures 1 channel of leakage current

● Power outage alarm

● HMI Programming: Setting of CT/PT Ratio, Phase Wiring, Communication and etc

● Standard&Certificate: CE; IEC

Local Configuration

● Keypads HMI for Setting (CT/PT ratio, Wiring and etc)

● Setting through Adjustment Software

 

       

Network

 

 

 

 

Dimension

 

 

 

 

 

Wiring

 

 

 

 

 

 

Installation

 

 

 

 

FAQ

 

Q:What's the biggest advantage of ADW300?

A:ADW300 has its built-in wireless communication module which allow it to realize 4G LTE, WiFi, NB-IoT, LoRa upstream communication without using extra IoT gateways. For the application scenarios when the meters can't be of centralized installation, ADW300 will usually be the best option for monitor 3-phase circuits that were far from each other.

 

Q:How should I deal with RS485 network communication malfunction?

A:First, check if the wiring of RS485 communication line was loosen or wired incorrectly.(like reversely wiring the A,B terminal).

      Next,inspect if the meter’s setting of address, baud rate, check bit was correct by using keypads on the meter.

 

Q:What if LoRa communication of meters malfunctioned?

A:First, use USB to RS485 serial converter to connect the meter with computer. Then use adjustment software to check if setting of meter is on consensus with the setting of master station.(setting of channel and spreading factor--SF)

     If setting remain the same, then it might be due to large interference of work site or the excessively far range between meter and host. In that case, it’s recommended to use chuck antenna or set a new master station nearby.

 

Q:What’s the difference between ADW300 and ADW300W

A:ADW300 has internal current transformers and can select compatible current transformer according to the site current to realized a secondary connection via CTs.

     ADW300W on the other hand, has external current transformers.(non-detachable or it will damage the meter) This kind of design extremely ease the wiring and installation if the work-site already has CTs.

 

Q:What do 3×57.7/100V,3×220/380V,3×380/660V,3×100V,3×380V,3×660V represent respectively?

A:The meter’s spec of 3*100V,3*57.7/100V is suitable for high voltage power system while pairing with PT(potential transformer or voltage transformer). Beside, 3*100V represent 3-phase 3-wire and 3*57.7/100V represent 3-phase 4-wire.

      The meter’s spec of 3*220/380V,3*380/660V,3*380V,3*660V is suitable for low voltage power system(directly connect with meter). Meanwhile,3*380V,3*660V represent 3-phase 3-wire and 3*220/380V,3*380/660V represent 3-phase 4-wire.

Other Question? Please contact us and we will reply you as soon as possible.