Estonia Acrel AMC200L-4E3/4G Digital Multi-Circuit AC Electricity Meter with 4G Communication For Tower Base Station Energy Consumption Monitoring

● Funtion:full power parameter measurement, Active 2DI + Passive 4DI + 2DO, 4 NTC Temperature, 1 T&H ● Circuit:4 or 8 Channels 3 phase or 12 or 24 channels single phase mA class current sensor ● RS485(Modbus RTU protocol), 4G ● Power supply: AC/DC 85-265V ● Applicaiton: telecom Base station,other multi channels applicaiton

Product Description

 

 

Overview

     

        

              AMC 200(L) AC multi-circuit intelligent power acquisition and monitoring device is mainly used for the full electric parameter measurement of multiple circuits, and can simultaneously access the current input of 8 three-phase circuits or 24 single-phase circuits at most.

 

    It can measure voltage, current, power, power factor and other parameters.

 

 

 

 

 

Dispaly

 

 

 

 

 

 

 

Application

 

 

 

 

Installation in Tower Base Station

 

 

 

 

 

Network

 

 

 

 

 

 

 

 

 

Models

 

 

 

 

Instrument model

basic skills

 

AMC 200 - 4 E 3

Can be connected to 4 three-phase AC circuits at the same time, can directly measure parameters such as voltage, current, power, power factor, etc., 6-way switch input (2-way active, 4-way passive), 2-way switch value output, 1-way RS485, 4 channels of NTC temperature measurement, 1 channel of temperature and humidity measurement

AMC200-4E3/4G

Can be connected to 4 three-phase AC circuits at the same time, can directly measure parameters such as voltage, current, power, power factor, etc., 6-way switch input (2-way active, 4-way passive), 2-way switch value output, 1-way RS485, 4 channels of NTC temperature measurement, 1 channel of temperature and humidity measurement , 4G communication

AMC200-4E3/NB

Can be connected to 4 three-phase AC circuits at the same time, can directly measure parameters such as voltage, current, power, power factor, etc., 6-way switch input (2-way active, 4-way passive), 2-way switch value output, 1-way RS485, 4 channels of NTC temperature measurement, 1 channel of temperature and humidity measurement , NB communication

AMC 200 - 8 E 3

Can be connected to 8 three-phase AC circuits at the same time, can directly measure parameters such as voltage, current, power, power factor, etc., 6-way switch input (2-way active, 4-way passive), 2-way switch value output, 1-way RS485, 4 channels of NTC temperature measurement, 1 channel of temperature and humidity measurement

AMC200-8E3/4G

Can be connected to 8 three-phase AC circuits at the same time, can directly measure parameters such as voltage, current, power, power factor, etc., 6-way switch input (2-way active, 4-way passive), 2-way switch value output, 1-way RS485, 4 channels of NTC temperature measurement, 1 channel of temperature and humidity measurement , 4G communication

AMC200-8E3/NB

Can be connected to 8 three-phase AC circuits at the same time, can directly measure parameters such as voltage, current, power, power factor, etc., 6-way switch input (2-way active, 4-way passive), 2-way switch value output, 1-way RS485, 4 channels of NTC temperature measurement, 1 channel of temperature and humidity measurement , NB communication

AMC 200L - 4 E 3

Can be connected to 4 three-phase AC circuits at the same time, can directly measure parameters such as voltage, current, power, power factor, etc., 6-way switch input (2-way active, 4-way passive), 2-way switch value output, 1-way RS485, 4 channels of NTC temperature measurement, 1 channel of temperature and humidity measurement , with LCD display

AMC200L-4E3/4G

Can be connected to 4 three-phase AC circuits at the same time, can directly measure parameters such as voltage, current, power, power factor, etc., 6-way switch input (2-way active, 4-way passive), 2-way switch value output, 1-way RS485, 4 channels of NTC temperature measurement, 1 channel of temperature and humidity measurement , 4G communication, with LCD display

AMC200L-4E3/NB

Can be connected to 4 three-phase AC circuits at the same time, can directly measure parameters such as voltage, current, power, power factor, etc., 6-way switch input (2-way active, 4-way passive), 2-way switch value output, 1-way RS485, 4 channels of NTC temperature measurement, 1 channel of temperature and humidity measurement , NB communication, with LCD display

AMC 200L - 8 E 3

Can be connected to 8 three-phase AC circuits at the same time, can directly measure parameters such as voltage, current, power, power factor, etc., 6-way switch input (2-way active, 4-way passive), 2-way switch value output, 1-way RS485, 4 channels of NTC temperature measurement, 1 channel of temperature and humidity measurement , with LCD display

AMC200L-8E3/4G

Can be connected to 8 three-phase AC circuits at the same time, can directly measure parameters such as voltage, current, power, power factor, etc., 6-way switch input (2-way active, 4-way passive), 2-way switch value output, 1-way RS485, 4 channels of NTC temperature measurement, 1 channel of temperature and humidity measurement , 4G communication, with LCD display

AMC200L-8E3/NB

Can be connected to 8 three-phase AC circuits at the same time, can directly measure parameters such as voltage, current, power, power factor, etc., 6-way switch input (2-way active, 4-way passive), 2-way switch value output, 1-way RS485, 4 channels of NTC temperature measurement, 1 channel of temperature and humidity measurement , NB communication, with LCD display

 

 

 

 

 

 

 

Function

 

 

 

The specific functions are as follows:

 

1、maximum 8 three-phase or 24 single-phase circuit full electric parameter measurement, current transformer external;

 

2、monitor the phase voltage/current, zero sequence current, frequency;

 

3、monitor the phase power, total power (active power, reactive power, apparent);

 

4、monitoring each phase power factor, total power factor, four-quadrant power statistics;

 

5、the use of simplified Chinese characters LCD display, English Version also. with historical power data and historical alarm information storage function:

 

a. By default, historical data is saved once a day at 0 o 'clock. Each channel and each item of data (total active power, total active power, and three-phase current) can be stored 1000 times.

 

b. The interval for storing historical data onsite is 15 minutes. Each channel and each item of data (total active energy, total active power, three-phase current)can be stored 5000 times.

 

c. 24 pieces of historical electricity data are stored on the monthly meter reading day.

 

d. Historical alarms are stored in real-time mode. A maximum of 500 historical alarms can be stored.

 

6、support over voltage, over current, phase break, DI linkage alarm output;

 

7、four passive switching input, two active switching input, two switching output;

 

8、standard RS485 communication, optional Modbus-RTU protocol or YD/T 1363 protocol;

 

9、one loop temperature and humidity measurement, 4 loops  NTC measurement;

 

 

 

 

       

Technical Parameters

 

 

 

 

 

Technical Parameters

technical indicators

enter

frequency

45~65Hz;

 

Voltage

Rated value: AC 3×220V/380V;

 

 

Overload: 1.2 times rated value (continuous); 2 times rated value/1 second;

 

 

Power consumption: ≤0.5VA (per channel);

 

electric current

Rated value: AC xxxA/50mA, external transformer is required;

 

 

Overload: 1.2 times rated value (continuous); 10 times rated value/1 second;

 

 

Power consumption: ≤0.5VA (per channel);

Function

 

Pulse output

Output mode: open collector optocoupler pulse (default 400imp/ kW h );

 

communication

Modbus-RTU protocol or YD/T 1363 protocol ;

Baud rate 1200~38400; optional 4G communication or NB communication;

 

open

close

quantity

enter

4 dry contact inputs, 2 active wet contact inputs (AC 220V);

 

 

output

Output mode: relay normally open contact output;

Contact capacity: AC 250V/3A or DC 30V/3A;

 

NTC temperature measurement

Temperature: -20~100°C (accuracy ±2°C);

 

Temperature and humidity measurement

Temperature: -20~100°C (accuracy ±2°C); Humidity: 20-90%RH (accuracy ±5%RH)

measurement accuracy

Frequency 0.05Hz, voltage and current level 0.5, active energy level 1;

Auxiliary power

AC/DC 85~265V; power consumption≤10VA;

safety

Power frequency withstand voltage

>AC 2kV/1min;

 

Insulation resistance

Input and output terminals to shell>100MΩ;

environment

Working temperature: -20℃~+60℃;

Storage temperature: -40℃~+70℃;

Relative humidity: ≤95% without condensation;

Altitude: ≤2500m;

Electromagnetic Compatibility

Surge (shock) immunity test level 4;

 

Electrostatic discharge immunity test level 3

 

Electrical fast transient burst immunity test level 4

 

 

 

 

 

 

 

Matching Transformers

 

 

 

        The current transformer is a crystal head interface, the primary side current is 100A-600A, and the secondary side output current is 50mA. If the current transformer is different, the customer can modify the current transformation ratio through the instrument interface or communication according to the actual usage. Transformer shown in Figure 1

 

 

 

 

model

Ratio

line length

precision

installation method

AKH-0.66/W-12NY 100A/50mA

100A/50mA

(1+0.2)m

Level 0.2

Closed type, crystal head interface

AKH-0.66/K-Φ16N 100A/50mA

100A/50mA

(1+0.2)m

Level 0.5

Open type, crystal head interface

AKH-0.66/W-20Y 200A/50mA

200A/50mA

(1+0.5)m

Level 0.2

Closed type, crystal head interface

AKH-0.66/K-Φ24N 200A/50mA

200A/50mA

(1+0.5)m

Level 0.5

Open type, crystal head interface

AKH-0.66/W-30NY 250A/50mA

250A/50mA

(1+0.5)m

Level 0.2

Closed type, crystal head interface

AKH-0.66/K-Φ24N 250A/50mA

250A/50mA

(1+0.5)m

Level 0.5

Open type, crystal head interface

AKH-0.66-TD-Φ60-NY

400A/50mA

(1+0.5)m

Level 0.2

Closed type, crystal head interface

AKH-0.66/K-Φ36N 400A/50mA

400A/50mA

(1+0.5)m

Level 0.5

Open type, crystal head interface

AKH-0.66-TD-Φ60-NY

600A/50mA

(1+0.5)m

Level 0.2

Closed type, crystal head interface

AKH-0.66/K-Φ36N 600A/50mA

600A/50mA

(1+0.5)m

Level 0.5

Open type, crystal head interface

 

 

 

 

 

 

 

Wiring

 

 

 

 

 

 

 

 

Dimension