PRODUCTS CENTER


Sweden Acrel AMC16Z-ZA Dual-circuit Data Center Energy Meter for Data Center with IOT Platform Energy Consumption Monitoring

● Monitoring: Dual Independent AC Incoming Circuits 3-phase (For Data Center) ● Measurement: Voltage, Current, Frequency, Active Power, Reactive Power, Power Factor and etc ● Power Quality: 2nd~63rd&Total Harmonic, Current&Voltage Unbalance and etc ● Communicaiton: RS485 (MODBUS-RTU) ● Rated Voltage: 220~264Vac L-N ● Rated Current: 1(6)A AC (via CTs) ● Standard&Certificate: CE; IEC; LVD

Product Description

 

 

Overview

     

 

      With the rapid development of data center, the energy consumption problem of data center is becoming more and more prominent. The energy management and power supply and distribution design of data center have become a hot issue.

        Efficient and reliable power distribution system scheme of data center is an effective way to improve the power consumption efficiency of data center and reduce the energy consumption of equipment. In order to realize energy saving in data center, it is necessary to monitor each electrical load first. However, there are many load  circuits in data center. Traditional measuring instruments cannot meet the requirements of cost, volume, installation, construction and other aspects. In this case, the multi-circuit monitoring device which is suitable for centralized monitoring in data center is necessary to be used.

      AMC16Z series AC precision power distribution monitoring device is specially designed for data center server power management.The device designed exquisite, can provide A + B 2 incoming and 96 outgoing’s electrical parameters, the input and output switch and the state of lightning protection device with real-time monitoring.

        All alarm threshold of measurement channels can be set in separate. Over-outgoing triggers system acoustooptic warning immediately. Highly integrated monitoring loop is realized in the volume of traditional instruments.

 

 

 

 

 

 

Dispaly

 

 

 

 

Application

 

 

 

 

 

 

Installation in Data Center

 

 

 

Network

 

 

 

 

 

Function

 

Dual AC Incoming Circuits Monitoring

● A+B Dual independent AC Circuits Monitoring

● Full Electrical Parameters Monitoring

● Power Quality Analyzing

 

Multiple Extra Function

● 6-channel DI (digital input)

● 2-channel DO (digital output)

● Temperature&Humidity Monitoring

● Leakage Current Monitoring

 

Multiple Extra Function

● 6-channel DI (digital input)

● 2-channel DO (digital output)

● Temperature&Humidity Monitoring

● Leakage Current Monitoring

 

 

       

 

Wiring Installation

 

 

 

 

 

 

 

 

Dimension