PRODUCTS CENTER


Timor-Leste Acrel AIM-T500L Industrial Insulation monitoring instrument

● Can monitor AC,DC or AC/DC under 690V mixed ungrounded system ● DC ungrounded system under 800V to ground resistance and capacitance value ● With fault warning and alarm function ● Fault location function ● 1 channel RS485 ● 1 CAN communication ● 2 replay outputs ● Self-check function ● LCD display ● SOE event record

Product Description

 

 

 

Overview

     

   

    With the development of industrial science and technology, residual current poses a great threat to industrial production safety. In order to improve the continuity and reliability of power supply, many important production sites adopt IT distribution system (ungrounded system).

 

      AIM-T500L series industrial insulation monitoring and fault  is specially developed by Acrel for IT distribution system in industrial occasions such as mine, glass factory, electric furnace and test equipment, ship, metallurgical plant, chemical plant, explosion hazard site, computer center and emergency power supply.

 

    The system has rich functions, including insulation resistance monitoring, insulation fault warning, insulation fault alarm, event recording, parameter setting, communication networking, etc. When the system has grounding fault, it can give a timely alarm and accurately locate the specific circuit of the fault to remind staff to check the fault in time. 

 

    The products conform to the requirements of enterprise standard Q/VDCL-26-2017 IT System Insulation Monitor.

 

 

 

 

 

 

Dispaly

 

 

 

 

 

 

 

Application

 

 

 

 

 

 

 

 

 

Features

 

 

 

1.  AIM-T500L insulation monitor

 

■ Monitor resistance of IT system real time, warning or alarm when the resistance exceeds the limit;

 

■ Relay alarm output, LED alarm output and other fault indication modes;

 

■ SOE function, convenient for staff to check and analyze the failure type and occurrence time, and judge the operation status of the system;

 

■ Self-check function, which can realize fault self-check of instrument hardware circuit;

 

■ Disconnect monitoring, real-time monitoring of PE/KE function grounding wire connection status;

 

■ RS485 interface, standard Modbus-RTU protocol;

 

■ CAN interface, custom protocol, used to interact with signal generator and fault locator;

 

■ Support manual/automatic reset modes;

 

■ Wide range of applications, suitable for AC, DC and AC-DC hybrid IT systems.

 

 

 

 

2. ASG200 test signal generator

 

■ Generate positioning signals and inject them into the ungrounded system;

 

■ Indicate the phase line where the fault is;

 

■ Manual startup positioning is supported;

 

■ CAN bus technology is adopted to facilitate data interaction with other devices in the system.

 

 

 

3. AIL200-12 insulation fault locator

 

■ Locate and indicate the loop where the fault is;

 

■ A single AIL200-12 can locate up to 12 loops;

 

■ Each IT system can be connected to a maximum of 90 locators, with a total of 1080 loops;

 

■ CAN bus technology is adopted to facilitate data interaction with other devices in the system.

 

 

 

4. AKH-0.66L series current transformer

 

■ Rated current ratio 5A:5mA , select model according to the rated current of the loop;

 

■ Coordinate with AIL200-12 insulation fault locator to achieve fault location.

 

 

 

 

 

Network

 

 

 

 

 

 

 

 

 

Technical Parameters

 

 

 

1. AIM-T500L insulation monitor

 

Item

Parameter

Accessory power supply

AC 85~265V; DC100~300V; 50/60Hz

Power dissipation

< 8W

System voltage

AC 0~690V; DC 0~800V; 40~460Hz

System application

IT system (online), Other system (offline)

Insulation monitoring

Measuring range

1k~10MΩ

Alarm range

10k~10MΩ

Resistance accuracy

1~10k,1k; 10k~10M, ±10%

system leakage capacitance

<500μF

Response time (Ce=1μF)

<5s

Internal parameters

Measuring voltage

<50V

Measuring current

<270μA

Internal DC impedance

≥180kΩ

Relay output

Error, Alarm, Warning

SOE

20 records (fault type, fault value, fault time)

Alarm type

LCD, LED indicator

Communication

RS485, Modbus-RTU; CAN, custom

Impulse voltage / Pollution Level

8kV/Ⅲ

EMC/ Radiation

IEC61326-2-4

Environment

Working temperature

-10 ~+65℃

Storage temperature

-20~+70℃

Relative humidity

<95%, without condensation

Altitude

≤2500m

 

 

2. ASG200 test signal generator

 

Accessory power supply

Voltage

AC 85~265V; DC100~300V

Power dissipation

<7W

IT system

Voltage

AC 220V; 3AC 0~690V; DC 0~800V

Fault locating

Response time

<5s

positing voltage

20V/5Hz

positing current

0~10mA

Response sensitivity

——

Internal parameters

EMC/ Radiation

IEC61326-2-4

Output

Relay output

——

Environment

Working temperature

-15~+55℃

 

 

3. AIL200-12 insulation fault locator

 

Accessory power supply

Voltage

AC 85~265V; DC100~300V

Power dissipation

<5W

IT system

Voltage

——

Fault locating

Response time

<12s

positing voltage

——

positing current

——

Response sensitivity

>0.5mA

Internal parameters

EMC/ Radiation

IEC61326-2-4

Output

Relay output

Alarm

Environment

Working temperature

-15~+55℃

 

 

 

 

4. AKH-0.66L series current transformer

 

Specifications

Rated current

Ratio

Accurate level

Rated load

Overload ratio

L-45

16-100A

5A:5mA

1 level

100Ω

10

L-80

100-250A

L-100

250-400A

L-150

400-800A

L-200

800-1500A

 

 

 

 

 

Related Products

 

 

 

Type and Name

Picture

Introduction

AIM-T500L insulation monitor

AIM-T500L insulation monitor adopts advanced microcontroller technology, high integration, small size, easy to install, intelligent, digital, networking in one. wide measuring range, fast reaction speed and large allowable system leakage capacitance.

ASG200 

test signal generator

ASG200 test signal generator can start and produce test signals in time when insulation fault occurs in the monitored IT system. It can coordinate with insulation fault locator to realize insulation fault location function and send fault phase line. 

AIL200-12 insulation fault locator

AIL200-12 insulation fault locator adopts high-precision signal detection circuit, and AKH-0.66L series current transformer, detection the signal of ASG200 test signal generator, accurate location of the insulation fault loop. every locator can locate 12 loops.

AKH-0.66 L series current transformer

AKH-0.66 L series current transformer is used with AIL200-12 insulation fault locator together, ratio is 1000:1. It is installed in the cabinet in the way of screw direct fixation.

 

 

 

 

 

 

 

Wiring

 

 

 

 

 

 

 

Dimension

 

 

 

 

 

 

Installation