morocco ARD2F CE Approved Smart Motor Protectors for Protecting Motors and Power Monitoring
Category:
Product Description
Overview
The ARD2F intelligent motor protector (hereinafter referred to as the protector) is suitable for low-voltage motor circuits with rated voltage up to 660V and integrates protection, measurement, control, communication, operation and maintenance.
Its perfect protection function ensures the safe operation of the motor, with logic programmable function, can meet a variety of control methods. The product adopts split structure, which is composed of main body, panel, mutual inductor and optional communication module, and can adapt to the installation of various cabinets.
Product Implementation standards: ——GB 14048.4-2020 Low-voltage switchgear and control gear -- Part 4-1: Contactors and motor starters -- Electromechanical contactors and motor starters (including motor protectors); ——JB/T 10736-2007 Low voltage motor protector.
Coding Rule

Dispaly

Application

Function
The ARD2F functional configuration is shown in below table:
|
Type Function |
Functional configuration |
||||
|
Standard function |
Optional function |
||||
|
Protection function |
Fixed time overload |
√ |
|
||
|
Inverse time overload |
√ |
|
|||
|
Starting timeout |
√ |
|
|||
|
Phase loss |
√ |
|
|||
|
Voltage unbalance |
√ |
|
|||
|
Current unbalance |
√ |
|
|||
|
Locked-Rotor |
√ |
|
|||
|
underload |
√ |
|
|||
|
External fault |
√ |
|
|||
|
Block |
√ |
|
|||
|
Temperature protection(PTC/NTC) |
√ |
|
|||
|
Residual current |
grounding |
√ |
|
||
|
leakage |
|
√(leakage) |
|||
|
Phase sequence |
√ |
|
|||
|
Under voltage |
√ |
|
|||
|
Over voltage |
√ |
|
|||
|
Under power |
√ |
|
|||
|
Over power |
√ |
|
|||
|
tE Time protect |
√ |
|
|||
|
Overflow protection |
√ |
|
|||
|
Alarm of starting times |
√ |
|
|||
|
Running time alarm |
√ |
|
|||
|
Fault frequency alarm |
√ |
|
|||
|
Control mode |
Protection mode |
√ |
|
||
|
Direct start mode |
|
√ |
|||
|
Two-step mode |
|||||
|
Two-speed mode |
|||||
|
Y-△ start mode |
|||||
|
Voltage loss restart |
|
√ |
|||
|
Communication |
1 channel Modbus-RTU communication |
|
√ |
||
|
2 channel Modbus-RTU communication |
|
√ |
|||
|
1 channel Profibus-DP communication |
|
√ |
|||
|
1 channel Modbus-RTU+1 channel Profibus-DP |
|
√ |
|||
|
Switching input |
9 channel DI(programmable) |
|
√ |
||
|
Relay output |
2 channel DO(programmable) |
√ |
|
||
|
5 channel DO(programmable) |
|
√ |
|||
|
Analog output |
1 channel DC4-20mA |
|
√ |
||
|
Event record |
Start record, stop record, DI displacement record, restart record, (support communication transmission and U disk export) |
|
√ |
||
|
Panel |
Liquid crystal display (LCD) |
Black and white dot matrix LCD display |
|
√ |
|
Additional features of ARD2F are shown in Table:
|
Additional function |
Code |
Additional function |
Code |
||
|
Starting control (including K function) |
Q |
Leakage protection |
L |
||
|
Switching input |
K |
4-20mA analog output |
M |
||
|
Temperature protection |
T |
Anti - electric shock function |
SU |
||
|
Alarm (Programmable output) |
J |
SOE event record |
SR |
||
|
1 channel communication |
Modbus_RTU |
C |
2 channels communication |
2路Modbus_RTU |
2C |
|
Profibus_DP |
CP |
Modbus+Profibus |
CCP |
||
|
Voltage function (phase sequence, power, power factor) |
U |
tE time protection |
tE |
||
|
Energy metering |
Ep |
|
|
||
Network

Product Features
■ Support fundamental and full-wave power parameter measurement (U, I, P, Q, S, PF, F, EP, EQ), voltage and current imbalance degree, voltage and current positive sequence, negative sequence, zero sequence component, three-phase voltage phase Angle, residual current.
■ Protection functions include overload inverse time, overload definite time, grounding, starting timeout, leakage, underload, locked-rotor, obstruction, short circuit, phase, overflow, imbalance (current, voltage, power, less power, overvoltage, undervoltage, phase sequence, temperature, external fault, tE time, running time alarm, fault alarm.
■ 9 channels programmable DI input, the default use of DC24V power supply, or external active wet contact can be selected (see the selection table).
■ 5 programmable DO output, to meet the direct starting, star - triangle starting, auto-transformer starting, and other starting modes, can be through the communication bus to achieve the master station to the motor remote control "start/stop".
■ Optional anti-shaking function: support immediate restart of shaking power and restart of voltage loss.
■ MODBUS_RTU and PROFIBUS DPV1 communication modules are available for selection.2 MODBUS_RTU communication channels or MODBUS-RTU+PROFIBUS DPV1 communication modules can be chosen.
■ Optional 1 channels DC4-20MA analog output interface, connected with DCS system, can realize the monitoring of field equipment.
■ With fault record, start record, stop record, DI displacement record, restart record and other records of various events, you can view a number of motor operation and maintenance information.
■ The display interface supports Chinese/English LIQUID crystal display
Dimension

Wiring