PRODUCTS CENTER
republic of liberia Acrel AKH-0.66/II 40II Series, 1000A/5A Closed Core AC CT Current Sensor Current Transformers for Smart Power Meters IOT Cloud Platform Energy Consumption Monitoring
Category:
Product Description
Overview
The seris of closed core current transformers are patented and flip designed. The appearance is nice and the wiring is convenient.
The transparent polycarbonate material is selected for the flip. We can clearly see the secondary lead wiring. It have square-round hole for both cable and bus passing through.
As alternating current signal acquisition element, it is generally matched with measuring instruments and widely used in electrical sets.
Coding Rule

Dispaly

Function

● Model: AKH-0.66/II 30II, 40II, 50II, 60II, 60x50II, 80II, 80x50II, 100II, 100x50II, 100x80II, 120x50II, 130x50II,
120x80II, 150x50II, 170x100II, 180x50II, 200x50II, 220x50II, 260x50II, 260x100II
● Accuracy: 1, or 0.5, or 0.2
● Rated secondary current: 1A or 5A
● Rated primary current: 100-6300A
● Rated frequency: 50/60Hz
● Continuous overload: 120%In


● Protection level: IP30
● Operating temperature:-30℃-+70℃
● Storage temperature:-40℃-+80℃
● Relative humidity, no condensation:90%
● Standard&Certificate: CE; IEC;
Models
|
Specification |
Rated current ratio (A) |
Precision degree and corresponding rated load (VA/Ω) |
Straight-through tums |
Bus spec(mm)/ number |
Installation |
||
|
0.2 |
0.5 |
1 |
|||||
|
30II |
100/5(1) |
|
|
1.5 |
1 |
30x10/1-2 |
A,C |
|
150/5(1) |
|
|
1.5 |
1 |
|||
|
200/5(1) |
|
2.5 |
|
1 |
|||
|
250/5(1) |
|
3.75 |
|
1 |
|||
|
300-450/5(1) |
|
5 |
|
1 |
|||
|
500/5(1) |
|
10 |
|
1 |
|||
|
600/5 |
|
10 |
|
1 |
|||
|
40II |
100/5(1) |
|
|
1.5 |
1 |
40×10/ 1-2 |
A,C |
|
150/5(1) |
|
|
2.5 |
1 |
|||
|
200/5(1) |
|
2.5 |
|
1 |
|||
|
250/5(1) |
|
3.75 |
|
1 |
|||
|
300-450/5(1) |
|
5 |
|
1 |
|||
|
500-800/5(1) |
|
10 |
|
1 |
|||
|
1000/5(1) |
10 |
|
|
1 |
|||
|
50II |
150 |
|
|
2.5 |
1 |
50×10/ 1-2 |
|
|
200-250/5(1) |
|
2.5 |
|
1 |
|||
|
300-450/5(1) |
|
5 |
|
1 |
|||
|
500-800/5(1) |
|
10 |
|
1 |
|||
|
1000-1250/5(1) |
10 |
|
|
1 |
|||
|
1500/5(1) |
20 |
|
|
1 |
|||
|
60II |
200-250/5(1) |
|
2.5 |
|
1 |
60×10/ 1-2 |
C |
|
300-450/5(1) |
|
5 |
|
1 |
|||
|
500-800/5(1) |
|
10 |
|
1 |
|||
|
1000-1250/5(1) |
10 |
|
|
1 |
|||
|
1500-2000/5(1) |
20 |
|
|
1 |
|||
|
2500/5(1) |
30 |
|
|
1 |
|||
|
60×50II |
200-250/5(1) |
|
2.5 |
|
1 |
60×10/ 1-3 |
D
|
|
300-450/5(1) |
|
5 |
|
1 |
|||
|
500-800/5(1) |
|
10 |
|
1 |
|||
|
1000-1250/5(1) |
10 |
|
|
1 |
|||
|
1500-2000/5(1) |
20 |
|
|
1 |
|||
|
2500/5(1) |
30 |
|
|
1 |
|||
|
80II |
200-250/5(1) |
|
2.5 |
|
1 |
80×10/ 1-2 |
|
|
300-450/5(1) |
|
5 |
|
1 |
|||
|
500-800/5(1) |
|
10 |
|
1 |
|||
|
1000-1250/5(1) |
10 |
|
|
1 |
|||
|
1500-2000/5(1) |
20 |
|
|
1 |
|||
|
2500-3000/5(1) |
30 |
|
|
1 |
|||
|
80×50II |
200-250/5(1) |
|
2.5 |
|
1 |
80×10/ 1-3 |
|
|
300-450/5(1) |
|
5 |
|
1 |
|||
|
500-800/5(1) |
|
10 |
|
1 |
|||
|
1000-1250/5(1) |
10 |
|
|
1 |
|||
|
1500-2000/5(1) |
20 |
|
|
1 |
|||
|
2500-3000/5(1) |
30 |
|
|
1 |
|||
|
100II |
300-450/5(1) |
|
5 |
|
1 |
100×10/ 1-2 |
|
|
500-800/5(1) |
|
10 |
|
1 |
|||
|
1000-1250/5(1) |
10 |
|
|
1 |
|||
|
1500-2000/5(1) |
20 |
|
|
1 |
|||
|
2500-4000/5(1) |
30 |
|
|
1 |
|||
|
|
300-450/5(1) |
|
5 |
|
1 |
100×10/ 1-3 |
|
|
500-800/5(1) |
|
10 |
|
1 |
|||
|
1000-1250/5(1) |
10 |
|
|
1 |
|||
|
1500-2000/5(1) |
20 |
|
|
1 |
|||
|
2500-4000/5(1) |
30 |
|
|
1 |
|||
|
100×80II |
600-800/5(1) |
|
10 |
|
1 |
100×10/ 1-4 |
|
|
1000-1250/5(1) |
10 |
|
|
1 |
|||
|
1500-2000/5(1) |
20 |
|
|
1 |
|||
|
2500-4000/5(1) |
30 |
|
|
1 |
|||
|
120×50II |
500-800/5(1) |
|
10 |
|
1 |
120×10/ 1-3 |
|
|
1000-1250/5(1) |
10 |
|
|
1 |
|||
|
1500-2000/5(1) |
20 |
|
|
1 |
|||
|
2500-5000/5(1) |
30 |
|
|
1 |
|||
|
130×50II |
600-800/5(1) |
|
10 |
|
1 |
125×10/1-3 130×10/1-3 60×10/2-6 |
|
|
1000-1250/5(1) |
10 |
|
|
1 |
|||
|
1500-2000/5(1) |
20 |
|
|
1 |
|||
|
2500-5000/5(1) |
30 |
|
|
1 |
|||
|
120×80II 150×50II |
1000-1250/5(1) |
10 |
|
|
1 |
120×10/ 1-4 |
D |
|
1500-2000/5(1) |
20 |
|
|
1 |
|||
|
2500-5000/5(1) |
30 |
|
|
1 |
|||
|
170×100II |
1500-2000/5(1) |
15 |
|
|
1 |
170×10/1-3 100×10/3-6 |
|
|
2500-5000/5(1) |
30 |
|
|
1 |
|||
|
180×50II |
1200-2000/5(1) |
10 |
|
|
1 |
180×10/1-3 |
|
|
2500-5000/5(1) |
30 |
|
|
1 |
|||
|
200×50II 220×50II 260×50II |
1500-2000/5(1) |
20 |
|
|
1 |
200×10/1-3 100×10/4-6 |
|
|
2500-5000/5(1) |
30 |
|
|
1 |
|||
|
260×100II |
1200-1500/5(1) |
10 |
|
|
1 |
250×10/2-5 125×10/4-10 |
|
|
1500-2000/5(1) |
20 |
|
|
1 |
|||
|
2500-6300/5(1) |
30 |
|
|
1 |
|||
Network

Dimensions
|
Size(mm)
Type |
Outline size |
Through size |
Mounting size |
Tolerance |
|||||
|
W |
H |
D |
Φ |
a |
e |
M |
N |
||
|
30II |
62 |
98 |
45 |
/ |
32 |
32 |
28 |
57.5 |
±1 |
|
40II |
78 |
103 |
45 |
/ |
43 |
31.5 |
48 |
57.5 |
|
|
50II |
87 |
113 |
45 |
/ |
52 |
32 |
30 |
57.5 |
|
|
60II |
102 |
125 |
45 |
/ |
61 |
33 |
42 |
57.5 |
|
|
60×50II |
102 |
142 |
45 |
/ |
62 |
51.5 |
42 |
57.5 |
|
|
80II |
117 |
119 |
45 |
/ |
82 |
32 |
60 |
57.5 |
|
|
80×50II |
120 |
141 |
45 |
/ |
82 |
52 |
60 |
57.5 |
|
|
100II |
145 |
125 |
45 |
/ |
103 |
35 |
80 |
57.5 |
|
|
100×50II |
145 |
155 |
50 |
/ |
103 |
55 |
80 |
70.5 |
|
|
100×80II |
152 |
190 |
55 |
/ |
104 |
85 |
80 |
70.5 |
|
|
120×50II |
174 |
168 |
48 |
/ |
122 |
53 |
79 |
70.5 |
|
|
120×80II |
160 |
193 |
60 |
/ |
122 |
72 |
56 |
70.5 |
|
|
130×50II |
176 |
160 |
50 |
/ |
135 |
55 |
86 |
70.5 |
|
|
150×50II |
210 |
176 |
55 |
/ |
155 |
55 |
103 |
70.5 |
|
|
180×50II |
239 |
181 |
60 |
/ |
185 |
55 |
40 |
83 |
|
|
200×50II |
247 |
175 |
55 |
/ |
202 |
61 |
188 |
83 |
|
|
220×50II |
280 |
190 |
60 |
/ |
225 |
55 |
65/55/65 |
83 |
|
|
260×50II |
320 |
191 |
60 |
/ |
265 |
55 |
65/55/65 |
83 |
|
|
170×100II |
227 |
230 |
60 |
/ |
172 |
105 |
103 |
83 |
|
|
260×100II |
308 |
218 |
63 |
/ |
265 |
104 |
183 |
83 |
|

Installation