PRODUCTS CENTER
● Measurement: kWh, U, I, P, Q, S, etc. ● Measures 2 channels of DC energy(optional) ● Measures bidirectional DC energy ● Communication: RS485(Modbus-RTU),2 channels of RS485(optional) ● Communication protocol: Modbus-RTU, DL/T 645-2007 ● Built-in Bipolar Power Source: Power Supply for Hall Effect CT (DC -12V ~ DC +12V) ● Voltage input range: DC0-1000V ● Input signal: Shunt:0-75mV;Hall sensor:0-20mA, 4-20mA, 0-5V, 0-10V and so on. ● 2DI/2DO ● Power supply: AC/DC 85-265V or DC24V(±10%) or DC48V(±10%) ● Accuracy: 1 or 0.5 (connected via shunt)(optional) ● Switch output: 2 Relay outputs, 2A/30VDC or 2A/250VAC ● Switch input: 2 dry contact inputs ● Pulse output: A second pulse output, an energy pulse output ● Display: 8 digits display U, I, P, Q, kWh and other energy consumption ● Average barrier-free working hours: ≥50000h ● Mounted: Din rail 35mm ● Standard & Certificate: CE; IEC; UL
● Measures active kWh (positive and negative), Reactive kWh (positive and negative), U, I, P, Q, S, PF, F, etc. ● Communication: 4G, WiFi, LoRa, LoRaWAN, RS485(Modbus-RTU) ● Harmonic on 2nd-31st ● 4DI+2DO ● Measure 1 way of residual current ● Monitor 4 cables' temperature ● Power failure alarm, 2DI/2DO ● Multi tariff ● Max demand and and occurrence time ● Frozen data on last 48 months, last 90 days ● Accuracy:Class 0.5 ● Active pulse output ● 12 bits section LCD display, background light ● 3 keys to communication and set parameters ● Rated voltage: 3×57.7/100V,3×220/380V,3×380/660V,3×100V, 3×380V,3×660V ● Rated current: 3×1(6)A ● Standard&Certificate: CE; IEC
● Measures active kWh (positive and negative), Reactive kWh (positive and negative), U, I, P, Q, S, PF, F, etc. ● Communication: 4G, WiFi, LoRa, LoRaWAN, RS485(Modbus-RTU) ● Harmonic on 2nd-31st ● 4DI+2DO ● Measure 1 way of residual current ● Monitor 4 cables' temperature ● Power failure alarm, 2DI/2DO ● Multi tariff ● Max demand and and occurrence time ● Frozen data on last 48 months, last 90 days ● Accuracy:Class 0.5 ● Active pulse output ● 12 bits section LCD display, background light ● 3 keys to communication and set parameters ● Rated voltage: 3×57.7/100V,3×220/380V,3×380/660V,3×100V, 3×380V,3×660V ● Rated current: 3×1(6)A ● Standard&Certificate: CE; IEC
● Measures active kWh (positive and negative), Reactive kWh (positive and negative), U, I, P, Q, S, PF, F, etc. ● Communication: 4G, WiFi, LoRa, LoRaWAN, RS485(Modbus-RTU) ● Harmonic on 2nd-31st ● 4DI+2DO ● Measure 1 way of residual current ● Monitor 4 cables' temperature ● Power failure alarm, 2DI/2DO ● Multi tariff ● Max demand and and occurrence time ● Frozen data on last 48 months, last 90 days ● Accuracy:Class 0.5 ● Active pulse output ● 12 bits section LCD display, background light ● 3 keys to communication and set parameters ● Rated voltage: 3×57.7/100V,3×220/380V,3×380/660V,3×100V, 3×380V,3×660V ● Rated current: 3×1(6)A ● Standard&Certificate: CE; IEC