ARD2F CE Approved Smart Motor Protectors for Protecting Motors and Power Monitoring

Series of products: Products

Series of products: Smart Motor Protectors

● U, I, P, S, PF, F, EP, Leakage, PTC/NTC ● Start control function ● 8 programmable DI ● 5 programmable DO ● Modbus-RTU or Profibus-DP communication ● 1 DC4-20mA analog output ● SOE ● Anti-shaking function ● Standard&Certificate: CE
Make an inquiry >
  • Product Description
  • Parameters
  • Q&A
  • Download
  •  

     

    Overview

         

     

              The ARD2F intelligent motor protector (hereinafter referred to as the protector) is suitable for low-voltage motor circuits with rated voltage up to 660V and integrates protection, measurement, control, communication, operation and maintenance.

     

          Its perfect protection function ensures the safe operation of the motor, with logic programmable function, can meet a variety of control methods. The product adopts split structure, which is composed of main body, panel, mutual inductor and optional communication module, and can adapt to the installation of various cabinets.

     

          Product Implementation standards: ——GB 14048.4-2020 Low-voltage switchgear and control gear -- Part 4-1: Contactors and motor starters -- Electromechanical contactors and motor starters (including motor protectors); ——JB/T 10736-2007 Low voltage motor protector.

     

     

     

     

     

    Coding Rule

     

     

     

     

     

     

     

    Dispaly

     

     

     

     

     

     

     

     

     

    Application

     

     

     

     

     

     

     

    Function

     

     

    The ARD2F functional configuration is shown in below table:

     

                                                   Type

    Function

    Functional configuration

    Standard function

    Optional function

    Protection function

    Fixed time overload

     

    Inverse time overload

     

    Starting timeout

     

    Phase loss

     

    Voltage unbalance

     

    Current unbalance

     

    Locked-Rotor

     

    underload

     

    External fault

     

    Block

     

    Temperature protection(PTC/NTC)

     

    Residual current

    grounding

     

    leakage

     

    √(leakage)

    Phase sequence

     

    Under voltage

     

    Over voltage

     

    Under power

     

    Over power

     

    tE Time protect

     

    Overflow protection

     

    Alarm of starting times

     

    Running time alarm

     

    Fault frequency alarm

     

    Control mode

    Protection mode

     

    Direct start mode

     

    Two-step mode

    Two-speed mode

    Y-△ start mode

    Voltage loss restart

     

    Communication

    1 channel Modbus-RTU communication

     

    2 channel Modbus-RTU communication

     

    1 channel Profibus-DP communication

     

    1 channel Modbus-RTU+1 channel Profibus-DP

     

    Switching input

    9 channel DI(programmable)

     

    Relay output

    2 channel DO(programmable)

     

    5 channel DO(programmable)

     

    Analog output

    1 channel DC4-20mA

     

    Event record

    Start record, stop record, DI displacement record, restart record, (support communication transmission and U disk export)

     

    Panel

    Liquid crystal display (LCD)

    Black and white dot matrix LCD display

     

     

     

     

    Additional features of ARD2F are shown in Table:

     

    Additional function

    Code

    Additional function

    Code

    Starting control (including K function)

    Q

    Leakage protection

    L

    Switching input

    K

    4-20mA analog output

    M

    Temperature protection

    T

    Anti - electric shock function

    SU

    Alarm (Programmable output)

    J

    SOE event record

    SR

    1 channel communication

    Modbus_RTU

    C

    2 channels communication

    2路Modbus_RTU

    2C

    Profibus_DP

    CP

    Modbus+Profibus

    CCP

    Voltage function (phase sequence, power, power factor)

    U

    tE time protection

    tE

    Energy metering

    Ep

     

     

     

     

           

    Network

     

     

     

     

     

     

     

     

     

     

     

    Product Features

     

     

    ■  Support fundamental and full-wave power parameter measurement (U, I, P, Q, S, PF, F, EP, EQ), voltage and current imbalance degree, voltage and current positive sequence, negative sequence, zero sequence component, three-phase voltage phase Angle, residual current.

     

    ■  Protection functions include overload inverse time, overload definite time, grounding, starting  timeout, leakage, underload, locked-rotor, obstruction, short circuit, phase, overflow, imbalance (current, voltage, power, less power, overvoltage, undervoltage, phase sequence, temperature, external fault, tE time, running time alarm, fault alarm.

     

    ■  9 channels programmable DI input, the default use of DC24V power supply, or external active wet contact can be selected (see the selection table).

     

    ■  5 programmable DO output, to meet the direct starting, star - triangle starting, auto-transformer starting, and other starting modes, can be through the communication bus to achieve the master station to the motor remote control "start/stop".

     

    ■  Optional anti-shaking function: support immediate restart of shaking power and restart of voltage loss.

     

    ■  MODBUS_RTU and PROFIBUS DPV1 communication modules are available for selection.2 MODBUS_RTU communication channels or MODBUS-RTU+PROFIBUS DPV1 communication modules can be chosen.

     

    ■  Optional 1 channels DC4-20MA analog output interface, connected with DCS system, can realize the monitoring of field equipment.

     

    ■  With fault record, start record, stop record, DI displacement record, restart record and other records of various events, you can view a number of motor operation and maintenance information.

     

    ■  The display interface supports Chinese/English LIQUID crystal display

     

     

     

     

     

    Dimension

     

     

     

     

     

     

     

    Wiring

     

     

     

     

     

     

     

     

     

    Package

     

     

     

     

     

     

     

    Product Description:
    • PView
    • high-performance
    • requirements
  •  

     

    Main parameters

     

     

       The corresponding relation between ARD2F current specification and the rated current and power of the applicable motor is shown in Table 1:

    Table 1

    Protector current specification (A)

    Ratio setting

    Primary side coil number of transformer

    Applicable scope of motor (kW)

    Suitable for motor Rated current range (A)

    1

    Support

    5circle

    0.12-999

    0.1-5000

    5

    1circle

    0.12-999

    0.5-5000

    1.6

    Does not support

    1circle

    0.12-0.55

    0.4-1.6

    6.3

    1circle

    0.75-2.2

    1.6-6.3

    25

    1circle

    3-11

    6.3-25

    100

    1circle

    15-45

    25-100

    250

    1circle

    55-132

    63-250

    800

    1circle

    160-250

    250-800

     

     

    Additional features of ARD2F are shown in Table 2:

    Table 2

    Additional function

    Code

    Additional function

    Code

    Starting control (including K function)

    Q

    Leakage protection

    L

    Switching input

    K

    4-20mA analog output

    M

    Temperature protection

    T

    Anti - electric shock function

    SU

    Alarm (Programmable output)

    J

    SOE event record

    SR

    1 channel communication

    Modbus_RTU

    C

    2 channels communication

    2路Modbus_RTU

    2C

    Profibus_DP

    CP

    Modbus+Profibus

    CCP

    Voltage function (phase sequence, power, power factor)

    U

    tE time protection

    tE

    Energy metering

    Ep

     

     

     

     

    See Table 3 for the ARD2F display module:

    Table 3

    Display module

    code

    90L

    LCD display, module size 98×60, opening 92×55 (unit:mm)

    Remarks:

    (1).Current measuring and 2 channels of relay output DO4(97.98).DO5(94.96.95) are standard for ARD2F.

    (2).When equipped with starting control, the protector provides no more than 2 starting relay for the sequence control of the closing/opening of two external contactors to realize different starting ways of motor (such as Y-Δ transformation starting, positive and negative rotation control, and self-coupling reduced-voltage starting, etc.)

    (3).The additional function SU and Q should be chosen together. Additional function SU is including U(voltage function) and SR(SOE event record).

    (4).The current specifications of 100A and below shall be the same type of current transformer. The transformer is equipped with a secondary line of about 1m. If you need special line length, please contact the manufacturer. The 250A and 800A current specifications use two other types of transformers with no secondary wires. See "External Dimensions and Installation" for the dimensions of the transformer.

    (5).The standard display cable is a network cable with a length of 1.5m. 3 meters and 5 meters are available for optional configuration. You can place an order and remark the corresponding cable length.

    (6).For customers who do not need display modules, a batch of optional several display modules can be used as a programmer, or the configuration software provided by the manufacturer can be used to configure parameters through computer software.

    (7).The temperature measurement support sensor type is PTC or NTC.。

    (8).After selecting the leakage function (L), each protector shall be equipped with a leakage transformer. Please refer to the "External Dimensions and Installation" section for the dimensions of the leakage transformer. The leakage transformer is equipped with a secondary wire of 2m±10cm. If other lengths are needed, please contact the manufacturer.

     

     

     

    Technical indicators

    ARD2F technical indicators are shown in Table 4:

    Table 4

    Technical parameters

    Technical indicators

    Protector auxiliary power supply

    AC85-265V/DC100-350V

    Rated working voltage of the motor

    AC220V / 380V / 660V,50Hz / 60Hz

    Rated operating current of the motor

    1 (0.1A-5000A)

    External current transformer

    5 (0.1A-5000A)

    1.6A(0.4A-1.6A)

    6.3A(1.6A-6.3A)

    25(6.3A-25A)

    100(25A-100A)

    250(63A-250A)

    800(250A-800A)

    Relay output contact capacity

    Impedance load

    AC250V.10A

    Switching input

    9 channels of passive dry contact (active DC110V, DC220V, AC220V input can be optional)

    Communication

    RS485 Modbus_RTU, Profobus_DP

    Environment

    Working temperature

    -10ºC~55ºC

    Storage temperature

    -25ºC~70ºC

    Relative humidity

    ≤95% No condensation, no corrosive gas

    Altitude

    ≤2000m

    Pollution levels

    Class 3

    Protection grade

    Main body IP20, split display module IP54 (installed on the cabinet panel)

    Installation category

    Level III

     

     

    Functional configuration

    The ARD2F functional configuration is shown in Table 5

    Table 5

                                                   Type

    Function

    Functional configuration

    Standard function

    Optional function

    Protection function

    Fixed time overload

     

    Inverse time overload

     

    Starting timeout

     

    Phase loss

     

    Voltage unbalance

     

    Current unbalance

     

    Locked-Rotor

     

    underload

     

    External fault

     

    Block

     

    Temperature protection(PTC/NTC)

     

    Residual current

    grounding

     

    leakage

     

    √(leakage)

    Phase sequence

     

    Under voltage

     

    Over voltage

     

    Under power

     

    Over power

     

    tE Time protect

     

    Overflow protection

     

    Alarm of starting times

     

    Running time alarm

     

    Fault frequency alarm

     

    Control mode

    Protection mode

     

    Direct start mode

     

    Two-step mode

    Two-speed mode

    Y-△ start mode

    Voltage loss restart

     

    Communication

    1 channel Modbus-RTU communication

     

    2 channel Modbus-RTU communication

     

    1 channel Profibus-DP communication

     

    1 channel Modbus-RTU+1 channel Profibus-DP

     

    Switching input

    9 channel DI(programmable)

     

    Relay output

    2 channel DO(programmable)

     

    5 channel DO(programmable)

     

    Analog output

    1 channel DC4-20mA

     

    Event record

    Start record, stop record, DI displacement record, restart record, (support communication transmission and U disk export)

     

    Panel

    Liquid crystal display (LCD)

    Black and white dot matrix LCD display

     

  •  

     