PRODUCT CENTER
Click to see the full breakdown
×
● Measurement: kWh, U, I, P, Q, S, etc.
● Can supply power ±12V to hall sensor
● Measures bidirectional DC energy
● Communication: RS485(Modbus-RTU)、Half duplex、Photoelectric isolation、Modbus-RTU / DL/T645-07、 Band:1200/2400/4800/9600、Infrared:1200
● Communication protocol: Modbus-RTU, DL/T 645-07
● Built-in Bipolar Power Source: Power Supply for Hall Effect CT (DC -12V ~ DC +12V)
● Voltage input range: DC0-1000V
● Input signal: Shunt:0-75mV;Hall sensor:0-20mA, 0-5V, etc.
● 4DI/2DO
● Power supply: AC/DC 85-265V or DC20-60VDC, or 100-350VDC
● Accuracy: 0.5
● Current Range: 0-2500A(External Shunt or Hall Current Sensor, the range can be set)
● Multiple Rate: Four time zones、two time table、fourteen time points、four multiple rates. (PZ72L-DE support only)
● Historical data statistics: Last 12 months of historical electricity(multiple rate electricity). (PZ72L-DE support only)
● Display: 8 digits display U, I, P, Q, kWh and other energy consumption
● Overload: It can work at normal status at 1.2 times of full load, and can continued work 1 second at 2 times of full load.
● Mounted: Din rail 35mm
● Standard & Certificate: CE; IEC;
Learn more
● Measurement: kWh, U, I, P, Q, S, etc.
● Can supply power ±12V to hall sensor
● Measures bidirectional DC energy
● Communication: RS485(Modbus-RTU)、Half duplex、Photoelectric isolation、Modbus-RTU / DL/T645-07、 Band:1200/2400/4800/9600、Infrared:1200
● Communication protocol: Modbus-RTU, DL/T 645-07
● Built-in Bipolar Power Source: Power Supply for Hall Effect CT (DC -12V ~ DC +12V)
● Voltage input range: DC0-1000V
● Input signal: Shunt:0-75mV;Hall sensor:0-20mA, 0-5V, etc.
● 4DI/2DO
● Power supply: AC/DC 85-265V or DC20-60VDC, or 100-350VDC
● Accuracy: 0.5
● Current Range: 0-2500A(External Shunt or Hall Current Sensor, the range can be set)
● Multiple Rate: Four time zones、two time table、fourteen time points、four multiple rates. (PZ72L-DE support only)
● Historical data statistics: Last 12 months of historical electricity(multiple rate electricity). (PZ72L-DE support only)
● Display: 8 digits display U, I, P, Q, kWh and other energy consumption
● Overload: It can work at normal status at 1.2 times of full load, and can continued work 1 second at 2 times of full load.
● Mounted: Din rail 35mm
● Standard & Certificate: CE; IEC;
Learn more
AMC96L-E4/KC CE Approved Digital 3 Phase Energy Meter For IOT Platform Energy Consumption Monitoring
● Measures active kWh (positive and negative), Reactive kWh (positive and negative), U, I, P, Q, S, PF, F, etc.
● Communication: RS485(Modbus-RTU)
● 4DI+2DO
● Harmonic on 2nd-31st
● Multi tariff
● Max demand and and occurrence time
● Frozen data on last 48 months, last 90 days
● Accuracy:Class 0.5
● Active pulse output
● 12 bits section LCD display, background light
● 4 keys to communication and set parameters
● Rated voltage: Rated voltage: AC 3×57.7V/100V(100V)、3×220V/380V(400V)、3×380V/660V(660V)(96 size only);
● Rated current: 1A, 5A
● Standard&Certificate: CE; IEC