● Funtion:full power parameter measurement, Active 2DI + Passive 4DI + 2DO, 4 NTC Temperature, 1 T&H
● Circuit: 4 or 8 Channels 3 phase or 12 or 24 channels single phase mA class current sensor
● RS485,Modbus RTU protocol
● Power supply: AC/DC 85-265V
● Applicaiton: telecom Base station,other multi channels applicaiton
Learn more
● Funtion:full power parameter measurement, Active 2DI + Passive 4DI + 2DO, 4 NTC Temperature, 1 T&H
● Circuit: 4 or 8 Channels 3 phase or 12 or 24 channels single phase mA class current sensor
● RS485,Modbus RTU protocol
● Power supply: AC/DC 85-265V
● Applicaiton: telecom Base station,other multi channels applicaiton
Learn more
● Funtion:full power parameter measurement, Active 2DI + Passive 4DI + 2DO, 4 NTC Temperature, 1 T&H
● Circuit: 4 or 8 Channels 3 phase or 12 or 24 channels single phase mA class current sensor
● RS485,Modbus RTU protocol
● Power supply: AC/DC 85-265V
● Applicaiton: telecom Base station,other multi channels applicaiton
Learn more
● Funtion:full power parameter measurement, Active 2DI + Passive 4DI + 2DO, 4 NTC Temperature, 1 T&H
● Circuit: 4 or 8 Channels 3 phase or 12 or 24 channels single phase mA class current sensor
● RS485,Modbus RTU protocol
● Power supply: AC/DC 85-265V
● Applicaiton: telecom Base station,other multi channels applicaiton
Learn more
● Funtion:full power parameter measurement, Active 2DI + Passive 4DI + 2DO, 4 NTC Temperature, 1 T&H
● Circuit: 4 or 8 Channels 3 phase or 12 or 24 channels single phase mA class current sensor
● RS485(Modbus RTU protocol), 4G
● Power supply: AC/DC 85-265V
● Applicaiton: telecom Base station,other multi channels applicaiton
Learn more
● Funtion:full power parameter measurement, Active 2DI + Passive 4DI + 2DO, 4 NTC Temperature, 1 T&H
● Circuit: 4 or 8 Channels 3 phase or 12 or 24 channels single phase mA class current sensor
● RS485,Modbus RTU protocol
● Power supply: AC/DC 85-265V
● Applicaiton: telecom Base station,other multi channels applicaiton
Learn more
● Funtion:full power parameter measurement, Active 2DI + Passive 4DI + 2DO, 4 NTC Temperature, 1 T&H
● Circuit:4 or 8 Channels 3 phase or 12 or 24 channels single phase mA class current sensor
● RS485(Modbus RTU protocol), 4G
● Power supply: AC/DC 85-265V
● Applicaiton: telecom Base station,other multi channels applicaiton
Learn more
● Funtion:full power parameter measurement, Active 2DI + Passive 4DI + 2DO, 4 NTC Temperature, 1 T&H
● Circuit: 4 or 8 Channels 3 phase or 12 or 24 channels single phase mA class current sensor
● RS485,Modbus RTU protocol
● Power supply: AC/DC 85-265V
● Applicaiton: telecom Base station,other multi channels applicaiton
Learn more
● Rated Current: AC250A, 100A
● Rated Voltage: 3x220V/380V AC (3P4W)
● Measure up to 4 circuit 3 phase
● Measure all electric parameters
● RS485 interface Modbus-RTU communication
● LCD Display; 35mm DIN Rail Installation
● Work with RJ45 port External Split core CTs
Learn more
AMC16Z-FDK48 Digital Multi Circuits DC Energy Meter For Data Center Energy Consumption Monitoring
● Designed specifically for the power supply management of server in the data center
● A+B independent 24 circuits(48 in total)
● U, I, P, Q, S, PF, kWh, kvarh
● 2nd-31st Harmonic
● kWh Class 0.5
● DIN 35 mm
Learn more
AMC16Z-FDK24 Digital Multi Circuits DC Energy Meter For Data Center Energy Consumption Monitoring
● Designed specifically for the power supply management of server in the data center
● A+B independent 24 circuits(48 in total)
● U, I, P, Q, S, PF, kWh, kvarh
● 2nd-31st Harmonic
● kWh Class 0.5
● DIN 35 mm
Learn more
● Monitoring: A+B Monitor 2*24 channels of Passive Switch State(For Data Center)
● Communicaiton: RS485 (MODBUS-RTU)
● Standard&Certificate: CE; IEC; LVD
Learn more
● Monitoring: A+B Monitor 2*24 channels of Active Switch State(For Data Center)
● Communicaiton: RS485 (MODBUS-RTU)
● Standard&Certificate: CE; IEC; LVD
Learn more
● Monitoring: Dual Independent A+B Dual independent DC Circuits Monitoring (For Data Center)
● Measurement: Voltage, Current, Frequency, etc
● Communicaiton: RS485 (MODBUS-RTU)
● Standard&Certificate: CE; IEC; LVD
Learn more
AMC16Z-FAK48 Digital Multi Circuits Energy Meter For Data Center Energy Consumption Monitoring
● Designed specifically for the power supply management of server in the data center
● A+B independent 24 circuits(48 in total)
● U, I, P, Q, S, PF, kWh, kvarh
● 2nd-31st Harmonic
● kWh Class 0.5
● DIN 35 mm
Learn more
AMC16Z-FAK24 Digital Multi Circuits Energy Meter For Data Center Energy Consumption Monitoring
● Designed specifically for the power supply management of server in the data center
● A+B independent 24 circuits(48 in total)
● U, I, P, Q, S, PF, kWh, kvarh
● 2nd-31st Harmonic
● kWh Class 0.5
● DIN 35 mm
Learn more
● Application: Prepaid & Postpaid (See Acrel Prepaid Solution)
● Monitoring: Up to 36 Circuits 1-phase or 12 Circuits 3-phase or Mixed
● Measurement: 1-phase&3-phase kWh (Class 0.5S), kVarh, Active Power, Reactive Power, Current, Voltage and etc
● Rated Voltage: 3x220/380V (50Hz)
● Rated Current: 80A AC (direct connection); 3x1(6)A AC (via CTs)
● Communication (Main Body): RS485 (MODBUS-RTU); Ethernet; Infrared
● Communication (Expanded): 4G; WiFi; LoRa
● Remote Control: DO&DI
● Installtion: 35mm DIN Rail
● Power Supply: 3*220/380V or 220V AC
● Standard&Certificate: CE
Learn more
● Application: Prepaid & Postpaid (See Acrel Prepaid Solution)
● Monitoring: Up to 36 Circuits 1-phase or 12 Circuits 3-phase or Mixed
● Measurement: 1-phase&3-phase kWh (Class 0.5S), kVarh, Active Power, Reactive Power, Current, Voltage and etc
● Rated Voltage: 3x220/380V (50Hz)
● Rated Current: 80A AC (direct connection); 3x1(6)A AC (via CTs)
● Communication (Main Body): RS485 (MODBUS-RTU); Ethernet; Infrared
● Communication (Expanded): 4G; WiFi; LoRa
● Remote Control: DO&DI
● Installtion: 35mm DIN Rail
● Power Supply: 3*220/380V or 220V AC
● Standard&Certificate: CE
Learn more
● Application: Prepaid & Postpaid (See Acrel Prepaid Solution)
● Monitoring: Up to 36 Circuits 1-phase or 12 Circuits 3-phase or Mixed
● Measurement: 1-phase&3-phase kWh (Class 0.5S), kVarh, Active Power, Reactive Power, Current, Voltage and etc
● Rated Voltage: 3x220/380V (50Hz)
● Rated Current: 80A AC (direct connection); 3x1(6)A AC (via CTs)
● Communication (Main Body): RS485 (MODBUS-RTU); Ethernet; Infrared
● Communication (Expanded): 4G; WiFi; LoRa
● Remote Control: DO&DI
● Installtion: 35mm DIN Rail
● Power Supply: 3*220/380V or 220V AC
● Standard&Certificate: CE
Learn more
● Application: Prepaid & Postpaid (See Acrel Prepaid Solution)
● Monitoring: Up to 36 Circuits 1-phase or 12 Circuits 3-phase or Mixed
● Measurement: 1-phase&3-phase kWh (Class 0.5S), kVarh, Active Power, Reactive Power, Current, Voltage and etc
● Rated Voltage: 3x220/380V (50Hz)
● Rated Current: 80A AC (direct connection); 3x1(6)A AC (via CTs)
● Communication (Main Body): RS485 (MODBUS-RTU); Ethernet; Infrared
● Communication (Expanded): 4G; WiFi; LoRa
● Remote Control: DO&DI
● Installtion: 35mm DIN Rail
● Power Supply: 3*220/380V or 220V AC
● Standard&Certificate: CE
Learn more
● Measures 4 channels of 3 phase circuits
● Measures 3 phase power, total power (active, reactive, apparent), U, I, P, Q, S, PF, F, zero sequence current, voltage/current phase angle, voltage/current degree of unbalance, etc.
● Communication: RS485(Modbus-RTU), LoRa
● Harmonic on 2nd-31st
● Multi tariff: 4 time zones 14Periods rate setting;
● Maximum Current, maximum power demand and real time Current, real time power demand;
● Record of voltage, current and power extreme of current month and last month;
● 200 event records, record the action of DIDO;
● Support over-voltage, over-current, phase failure, DI linkage and other alarm output;
● Accuracy: Class 1
● 12 channel Switching inputs+4 channel Switching outputs;
● 12 channel external NTC temperature +4 channel residual current measurement (leakage current);
● Rated voltage: 3×220/380V
● Rated current: 5A( secondary transforming), 100A, 400A, 600A.
Learn more
● Measures 4 channels of 3 phase circuits
● Measures 3 phase power, total power (active, reactive, apparent), U, I, P, Q, S, PF, F, zero sequence current, voltage/current phase angle, voltage/current degree of unbalance, etc.
● Communication: RS485(Modbus-RTU)
● Harmonic on 2nd-31st
● Multi tariff: 4 time zones 14Periods rate setting;
● Maximum Current, maximum power demand and real time Current, real time power demand;
● Record of voltage, current and power extreme of current month and last month;
● 200 event records, record the action of DIDO;
● Support over-voltage, over-current, phase failure, DI linkage and other alarm output;
● Accuracy: Class 1
● 12 channel Switching inputs+4 channel Switching outputs;
● 12 channel external NTC temperature +4 channel residual current measurement (leakage current);
● Rated voltage: 3×220/380V
● Rated current: 5A( secondary transforming), 100A, 400A, 600A.
Learn more
● Measures 4 channels of 3 phase circuits
● Measures 3 phase power, total power (active, reactive, apparent), U, I, P, Q, S, PF, F, zero sequence current, voltage/current phase angle, voltage/current degree of unbalance, etc.
● Communication: RS485(Modbus-RTU)
● Harmonic on 2nd-31st
● Multi tariff: 4 time zones 14Periods rate setting;
● Maximum Current, maximum power demand and real time Current, real time power demand;
● Record of voltage, current and power extreme of current month and last month;
● 200 event records, record the action of DIDO;
● Support over-voltage, over-current, phase failure, DI linkage and other alarm output;
● Accuracy: Class 1
● 12 channel Switching inputs+4 channel Switching outputs;
● 12 bits section LCD display, background light
● 12 channel external NTC temperature +4 channel residual current measurement (leakage current);
● Rated voltage: 3×220/380V
● Rated current: 5A( secondary transforming), 100A, 400A, 600A.
Learn more