ABAT100 CE Approved Digital 3 Phase Energy Meter For IOT Platform Energy Consumption Monitoring
● Measures active kWh (positive and negative), Reactive kWh (positive and negative), U, I, P, Q, S, PF, F, etc.
● Communication: RS485(Modbus-RTU), link to IOT Platform
● Harmonic on 2nd-31st
● Multi tariff
● Max demand and and occurrence time
● Frozen data on last 48 months, last 90 days
● Accuracy:Class 0.5S
● Active pulse output
● 12 bits section LCD display, background light
● 3 keys to communication and set parameters
● Rated voltage: 3×100V, 3×380V, 3×57.7/100V, 3×230/400V (withstand 120% load)
● Rated current: 3×1(6)A, 3×10(80)A (withstand 120% load)
● Standard&Certificate: MID; CE; IEC
Learn more
AMC16Z-FDK48 Digital Multi Circuits DC Energy Meter For Data Center Energy Consumption Monitoring
● Designed specifically for the power supply management of server in the data center
● A+B independent 24 circuits(48 in total)
● U, I, P, Q, S, PF, kWh, kvarh
● 2nd-31st Harmonic
● kWh Class 0.5
● DIN 35 mm
Learn more
AMC16Z-FDK24 Digital Multi Circuits DC Energy Meter For Data Center Energy Consumption Monitoring
● Designed specifically for the power supply management of server in the data center
● A+B independent 24 circuits(48 in total)
● U, I, P, Q, S, PF, kWh, kvarh
● 2nd-31st Harmonic
● kWh Class 0.5
● DIN 35 mm
Learn more
● Monitoring: A+B Monitor 2*24 channels of Passive Switch State(For Data Center)
● Communicaiton: RS485 (MODBUS-RTU)
● Standard&Certificate: CE; IEC; LVD
Learn more
● Monitoring: A+B Monitor 2*24 channels of Active Switch State(For Data Center)
● Communicaiton: RS485 (MODBUS-RTU)
● Standard&Certificate: CE; IEC; LVD
Learn more
● Monitoring: Dual Independent A+B Dual independent DC Circuits Monitoring (For Data Center)
● Measurement: Voltage, Current, Frequency, etc
● Communicaiton: RS485 (MODBUS-RTU)
● Standard&Certificate: CE; IEC; LVD
Learn more
AMC16Z-FAK48 Digital Multi Circuits Energy Meter For Data Center Energy Consumption Monitoring
● Designed specifically for the power supply management of server in the data center
● A+B independent 24 circuits(48 in total)
● U, I, P, Q, S, PF, kWh, kvarh
● 2nd-31st Harmonic
● kWh Class 0.5
● DIN 35 mm
Learn more
AMC16Z-FAK24 Digital Multi Circuits Energy Meter For Data Center Energy Consumption Monitoring
● Designed specifically for the power supply management of server in the data center
● A+B independent 24 circuits(48 in total)
● U, I, P, Q, S, PF, kWh, kvarh
● 2nd-31st Harmonic
● kWh Class 0.5
● DIN 35 mm
Learn more
● Monitoring: Dual Independent AC Incoming Circuits 3-phase (For Data Center)
● Measurement: Voltage, Current, Frequency, Active Power, Reactive Power, Power Factor and etc
● Power Quality: 2nd~63rd&Total Harmonic, Current&Voltage Unbalance and etc
● Communicaiton: RS485 (MODBUS-RTU)
● Rated Voltage: 220~264Vac L-N
● Rated Current: 1(6)A AC (via CTs)
● Standard&Certificate: CE; IEC; LVD
Learn more
● Monitoring: Dual Independent AC Incoming Circuits 3-phase (For Data Center)
● Measurement: Voltage, Current, Frequency, Active Power, Reactive Power, Power Factor and etc
● Power Quality: 2nd~63rd&Total Harmonic, Current&Voltage Unbalance and etc
● Communicaiton: RS485 (MODBUS-RTU)
● Rated Voltage: 220~264Vac L-N
● Rated Current: 1(6)A AC (via CTs)
● Standard&Certificate: CE; IEC; LVD
Learn more