PRODUCT CENTER
Click to see the full breakdown
×
AMC16Z-FDK48 Digital Multi Circuits DC Energy Meter For Data Center Energy Consumption Monitoring
● Designed specifically for the power supply management of server in the data center
● A+B independent 24 circuits(48 in total)
● U, I, P, Q, S, PF, kWh, kvarh
● 2nd-31st Harmonic
● kWh Class 0.5
● DIN 35 mm
Learn more
AMC16Z-FDK24 Digital Multi Circuits DC Energy Meter For Data Center Energy Consumption Monitoring
● Designed specifically for the power supply management of server in the data center
● A+B independent 24 circuits(48 in total)
● U, I, P, Q, S, PF, kWh, kvarh
● 2nd-31st Harmonic
● kWh Class 0.5
● DIN 35 mm
Learn more
● Monitoring: A+B Monitor 2*24 channels of Passive Switch State(For Data Center)
● Communicaiton: RS485 (MODBUS-RTU)
● Standard&Certificate: CE; IEC; LVD
Learn more
● Monitoring: A+B Monitor 2*24 channels of Active Switch State(For Data Center)
● Communicaiton: RS485 (MODBUS-RTU)
● Standard&Certificate: CE; IEC; LVD
Learn more
● Monitoring: Dual Independent A+B Dual independent DC Circuits Monitoring (For Data Center)
● Measurement: Voltage, Current, Frequency, etc
● Communicaiton: RS485 (MODBUS-RTU)
● Standard&Certificate: CE; IEC; LVD
Learn more
AMC16Z-FAK48 Digital Multi Circuits Energy Meter For Data Center Energy Consumption Monitoring
● Designed specifically for the power supply management of server in the data center
● A+B independent 24 circuits(48 in total)
● U, I, P, Q, S, PF, kWh, kvarh
● 2nd-31st Harmonic
● kWh Class 0.5
● DIN 35 mm
Learn more
AMC16Z-FAK24 Digital Multi Circuits Energy Meter For Data Center Energy Consumption Monitoring
● Designed specifically for the power supply management of server in the data center
● A+B independent 24 circuits(48 in total)
● U, I, P, Q, S, PF, kWh, kvarh
● 2nd-31st Harmonic
● kWh Class 0.5
● DIN 35 mm
Learn more
● Monitoring: Dual Independent AC Incoming Circuits 3-phase (For Data Center)
● Measurement: Voltage, Current, Frequency, Active Power, Reactive Power, Power Factor and etc
● Power Quality: 2nd~63rd&Total Harmonic, Current&Voltage Unbalance and etc
● Communicaiton: RS485 (MODBUS-RTU)
● Rated Voltage: 220~264Vac L-N
● Rated Current: 1(6)A AC (via CTs)
● Standard&Certificate: CE; IEC; LVD
Learn more
● Monitoring: Dual Independent AC Incoming Circuits 3-phase (For Data Center)
● Measurement: Voltage, Current, Frequency, Active Power, Reactive Power, Power Factor and etc
● Power Quality: 2nd~63rd&Total Harmonic, Current&Voltage Unbalance and etc
● Communicaiton: RS485 (MODBUS-RTU)
● Rated Voltage: 220~264Vac L-N
● Rated Current: 1(6)A AC (via CTs)
● Standard&Certificate: CE; IEC; LVD
Learn more
● Measurement: kWh, U, I, P, Q, S, etc.
● Measures 2 channels of DC energy(optional)
● Measures bidirectional DC energy
● Communication: RS485(Modbus-RTU),2 channels of RS485(optional)
● Communication protocol: Modbus-RTU, DL/T 645-2007
● Built-in Bipolar Power Source: Power Supply for Hall Effect CT (DC -12V ~ DC +12V)
● Voltage input range: DC0-1000V
● Input signal: Shunt:0-75mV;Hall sensor:0-20mA, 4-20mA, 0-5V, 0-10V and so on.
● 2DI/2DO
● Power supply: AC/DC 85-265V or DC24V(±10%) or DC48V(±10%)
● Accuracy: 1 or 0.5 (connected via shunt)(optional)
● Switch output: 2 Relay outputs, 2A/30VDC or 2A/250VAC
● Switch input: 2 dry contact inputs
● Pulse output: A second pulse output, an energy pulse output
● Display: 8 digits display U, I, P, Q, kWh and other energy consumption
● Average barrier-free working hours: ≥50000h
● Mounted: Din rail 35mm
● Standard & Certificate: CE; IEC; UL
Learn more
● Measurement: kWh, U, I, P, Q, S, etc.
● Measures 2 channels of DC energy(optional)
● Measures bidirectional DC energy
● Communication: RS485(Modbus-RTU),2 channels of RS485(optional)
● Communication protocol: Modbus-RTU, DL/T 645-2007
● Built-in Bipolar Power Source: Power Supply for Hall Effect CT (DC -12V ~ DC +12V)
● Voltage input range: DC0-1000V
● Input signal: Shunt:0-75mV;Hall sensor:0-20mA, 4-20mA, 0-5V, 0-10V and so on.
● 2DI/2DO
● Power supply: AC/DC 85-265V or DC24V(±10%) or DC48V(±10%)
● Accuracy: 1 or 0.5 (connected via shunt)(optional)
● Switch output: 2 Relay outputs, 2A/30VDC or 2A/250VAC
● Switch input: 2 dry contact inputs
● Pulse output: A second pulse output, an energy pulse output
● Display: 8 digits display U, I, P, Q, kWh and other energy consumption
● Average barrier-free working hours: ≥50000h
● Mounted: Din rail 35mm
● Standard & Certificate: CE; IEC; UL
Learn more
● Application: Prepaid & Postpaid (See Acrel Prepaid Solution)
● Monitoring: Up to 36 Circuits 1-phase or 12 Circuits 3-phase or Mixed
● Measurement: 1-phase&3-phase kWh (Class 0.5S), kVarh, Active Power, Reactive Power, Current, Voltage and etc
● Rated Voltage: 3x220/380V (50Hz)
● Rated Current: 80A AC (direct connection); 3x1(6)A AC (via CTs)
● Communication (Main Body): RS485 (MODBUS-RTU); Ethernet; Infrared
● Communication (Expanded): 4G; WiFi; LoRa
● Remote Control: DO&DI
● Installtion: 35mm DIN Rail
● Power Supply: 3*220/380V or 220V AC
● Standard&Certificate: CE
Learn more