Products

PRODUCT CENTER

Click to see the full breakdown
×

Acrel APM520/CE CE Approved Digital 3 Phase Ethernet Energy Meter For IOT Platform Energy Consumption Monitoring

● 3 phase 3 wires, 3 phase 4 wires ● Rated voltage: AC 3*57.7/100V, AC 3*63.5/110V, AC 3*230/400V, AC 3*400/690V (96 Shape only); ● Rated current: 1A, 5A ● Accuracy: IEC 62053-22 0.5S class (0.2S accuracy when S is selected) ● Communication: RS485(Modbus-RTU)、Ethernet (MODBUS-TCP)、WiFi、4G ● 2DI+2DO ● kWh  (positive and negative)、kVarh (positive and negative) ● U, I, P, Q, S, PF, Hz, etc. ● A, B, C phase positive active kWh ● Four-quadrant energy、Split phase electricity、Apparent energy、Multi-rate energy ● 2~63ST Voltage and current harmonic(optional) ● Multi tariff: Adapt 4 time zones, 2 time interval lists, 14 time interval by day and 4 tariff rates(optional) ● Max demanded kWh and time happened(optional)
Learn more

Acrel APM520/4G CE Approved Digital 3 Phase 4G Energy Meter For IOT Platform Energy Consumption Monitoring

● 3 phase 3 wires, 3 phase 4 wires ● Rated voltage: AC 3*57.7/100V, AC 3*63.5/110V, AC 3*230/400V, AC 3*400/690V (96 Shape only); ● Rated current: 1A, 5A ● Accuracy: IEC 62053-22 0.5S class (0.2S accuracy when S is selected) ● Communication: RS485(Modbus-RTU)、Ethernet (MODBUS-TCP)、WiFi、4G ● 2DI+2DO ● kWh  (positive and negative)、kVarh (positive and negative) ● U, I, P, Q, S, PF, Hz, etc. ● A, B, C phase positive active kWh ● Four-quadrant energy、Split phase electricity、Apparent energy、Multi-rate energy ● 2~63ST Voltage and current harmonic(optional) ● Multi tariff: Adapt 4 time zones, 2 time interval lists, 14 time interval by day and 4 tariff rates(optional) ● Max demanded kWh and time happened(optional)
Learn more

Acrel APM520/WF CE Approved Digital 3 Phase WiFi Energy Meter For IOT Platform Energy Consumption Monitoring

● 3 phase 3 wires, 3 phase 4 wires ● Rated voltage: AC 3*57.7/100V, AC 3*63.5/110V, AC 3*230/400V, AC 3*400/690V (96 Shape only); ● Rated current: 1A, 5A ● Accuracy: IEC 62053-22 0.5S class (0.2S accuracy when S is selected) ● Communication: RS485(Modbus-RTU)、Ethernet (MODBUS-TCP)、WiFi、4G ● 2DI+2DO ● kWh  (positive and negative)、kVarh (positive and negative) ● U, I, P, Q, S, PF, Hz, etc. ● A, B, C phase positive active kWh ● Four-quadrant energy、Split phase electricity、Apparent energy、Multi-rate energy ● 2~63ST Voltage and current harmonic(optional) ● Multi tariff: Adapt 4 time zones, 2 time interval lists, 14 time interval by day and 4 tariff rates(optional) ● Max demanded kWh and time happened(optional)
Learn more

Acrel APM510/CE CE Approved Digital 3 Phase Ethernet Energy Meter For IOT Platform Energy Consumption Monitoring

● 3 phase 3 wires, 3 phase 4 wires ● Rated voltage: AC 3*57.7/100V, AC 3*63.5/110V, AC 3*230/400V, AC 3*400/690V (96 Shape only); ● Rated current: 1A, 5A ● Accuracy: IEC 62053-22 0.5S class (0.2S accuracy when S is selected) ● Communication: RS485(Modbus-RTU)、Ethernet (MODBUS-TCP)、WiFi、4G ● 2DI+2DO ● kWh  (positive and negative)、kVarh (positive and negative) ● U, I, P, Q, S, PF, Hz, etc. ● A, B, C phase positive active kWh ● Four-quadrant energy、Split phase electricity、Apparent energy、Multi-rate energy ● 2~63ST Voltage and current harmonic(optional) ● Multi tariff: Adapt 4 time zones, 2 time interval lists, 14 time interval by day and 4 tariff rates(optional) ● Max demanded kWh and time happened(optional)
Learn more

Acrel APM510/4G CE Approved Digital 3 Phase 4G Energy Meter For IOT Platform Energy Consumption Monitoring

● 3 phase 3 wires, 3 phase 4 wires ● Rated voltage: AC 3*57.7/100V, AC 3*63.5/110V, AC 3*230/400V, AC 3*400/690V (96 Shape only); ● Rated current: 1A, 5A ● Accuracy: IEC 62053-22 0.5S class (0.2S accuracy when S is selected) ● Communication: RS485(Modbus-RTU)、Ethernet (MODBUS-TCP)、WiFi、4G ● 2DI+2DO ● kWh  (positive and negative)、kVarh (positive and negative) ● U, I, P, Q, S, PF, Hz, etc. ● A, B, C phase positive active kWh ● Four-quadrant energy、Split phase electricity、Apparent energy、Multi-rate energy ● 2~63ST Voltage and current harmonic(optional) ● Multi tariff: Adapt 4 time zones, 2 time interval lists, 14 time interval by day and 4 tariff rates(optional) ● Max demanded kWh and time happened(optional)
Learn more

Acrel APM510/WF CE Approved Digital 3 Phase WiFi Energy Meter For IOT Platform Energy Consumption Monitoring

● 3 phase 3 wires, 3 phase 4 wires ● Rated voltage: AC 3*57.7/100V, AC 3*63.5/110V, AC 3*230/400V, AC 3*400/690V (96 Shape only); ● Rated current: 1A, 5A ● Accuracy: IEC 62053-22 0.5S class (0.2S accuracy when S is selected) ● Communication: RS485(Modbus-RTU)、Ethernet (MODBUS-TCP)、WiFi、4G ● 2DI+2DO ● kWh  (positive and negative)、kVarh (positive and negative) ● U, I, P, Q, S, PF, Hz, etc. ● A, B, C phase positive active kWh ● Four-quadrant energy、Split phase electricity、Apparent energy、Multi-rate energy ● 2~63ST Voltage and current harmonic(optional) ● Multi tariff: Adapt 4 time zones, 2 time interval lists, 14 time interval by day and 4 tariff rates(optional) ● Max demanded kWh and time happened(optional)
Learn more

Acrel APM520 CE Approved Digital 3 Phase Energy Meter For IOT Platform Energy Consumption Monitoring

● 3 phase 3 wires, 3 phase 4 wires ● Rated voltage: AC 3*57.7/100V, AC 3*63.5/110V, AC 3*230/400V, AC 3*400/690V (96 Shape only); ● Rated current: 1A, 5A ● Accuracy: IEC 62053-22 0.5S class (0.2S accuracy when S is selected) ● Communication: RS485(Modbus-RTU)、Ethernet (MODBUS-TCP)、WiFi、4G ● 2DI+2DO ● kWh  (positive and negative)、kVarh (positive and negative) ● U, I, P, Q, S, PF, Hz, etc. ● A, B, C phase positive active kWh ● Four-quadrant energy、Split phase electricity、Apparent energy、Multi-rate energy ● 2~63ST Voltage and current harmonic(optional) ● Multi tariff: Adapt 4 time zones, 2 time interval lists, 14 time interval by day and 4 tariff rates(optional) ● Max demanded kWh and time happened(optional)
Learn more

Acrel APM510 CE Approved Digital 3 Phase Energy Meter For IOT Platform Energy Consumption Monitoring

● 3 phase 3 wires, 3 phase 4 wires ● Rated voltage: AC 3*57.7/100V, AC 3*63.5/110V, AC 3*230/400V, AC 3*400/690V (96 Shape only); ● Rated current: 1A, 5A ● Accuracy: IEC 62053-22 0.5S class (0.2S accuracy when S is selected) ● Communication: RS485(Modbus-RTU)、Ethernet (MODBUS-TCP)、WiFi、4G ● 2DI+2DO ● kWh  (positive and negative)、kVarh (positive and negative) ● U, I, P, Q, S, PF, Hz, etc. ● A, B, C phase positive active kWh ● Four-quadrant energy、Split phase electricity、Apparent energy、Multi-rate energy ● 2~63ST Voltage and current harmonic(optional) ● Multi tariff: Adapt 4 time zones, 2 time interval lists, 14 time interval by day and 4 tariff rates(optional) ● Max demanded kWh and time happened(optional)
Learn more

Acrel DL300-EYNK/4GHW(DTSY1352-NK/4GHW) 4G Three Phase Prepaid Energy Meter with RS485 Built-in Magnetic Relay for Acrel IOT Platform Energy Prepayment by Online

● 3 phase 4 wires ● Rated voltage: 3*220V/380V ● Rated current: 3*1(6)A, or 3*10(80)A ● Prepaid function, support prepayment by online, remote switch on/off  ● Overload: 1.2 times rating (continuous), 2 times the rating for 1 second            ● Accuracy: Class 0.5S ● Communication: RS485(Modbus-RTU)、4G ● kWh  (positive and negative), kVarh (positive and negative), U, I, P, Q, S, PF, Hz, etc. ● Communication, and other parameters can be programmable by the key ● LCD dispaly: Segmented LCD display ● Active pulse output ● LCD dispaly: Segmented LCD display ● Grid frequency: 45~65Hz, error ±0.5% ● Standard & Certificate: CE;
Learn more

Acrel DL300-EYNK/FWF(DTSY1352-NK/FWF) WiFi Three Phase Prepaid Energy Meter with RS485 Built-in Magnetic Relay for Acrel IOT Platform Energy Prepayment by Online

● 3 phase 4 wires ● Rated voltage: 3*220V/380V ● Rated current: 3*1(6)A, or 3*10(80)A ● Prepaid function, support prepayment by online, remote switch on/off  ● Overload: 1.2 times rating (continuous), 2 times the rating for 1 second            ● Accuracy: Class 0.5S ● Communication: RS485(Modbus-RTU)、WiFi ● kWh  (positive and negative), kVarh (positive and negative), U, I, P, Q, S, PF, Hz, etc. ● Communication, and other parameters can be programmable by the key ● LCD dispaly: Segmented LCD display ● Active pulse output ● LCD dispaly: Segmented LCD display ● Grid frequency: 45~65Hz, error ±0.5% ● Standard & Certificate: CE;
Learn more

Acrel ADL300-EYZ(DTSY1352-RF) Three Phase Prepaid Energy Meter with RS485 Built-in Magnetic Relay for Acrel IOT Platform Energy Prepayment by Online or Cards

● 3 phase 4 wires ● Rated voltage: 3*220V/380V ● Rated current: 3*1(6)A, or 3*10(80)A ● Prepaid function, support prepayment by online or cards, remote switch on/off  ● Overload: 1.2 times rating (continuous), 2 times the rating for 1 second            ● Accuracy: Class 0.5S ● Communication: RS485(Modbus-RTU) ● kWh  (positive and negative), kVarh (positive and negative), U, I, P, Q, S, PF, Hz, etc. ● Communication, and other parameters can be programmable by the key ● LCD dispaly: Segmented LCD display ● Active pulse output ● LCD dispaly: Segmented LCD display ● Grid frequency: 45~65Hz, error ±0.5% ● Standard & Certificate: CE;
Learn more

Acrel ADL300-EYRF(DTSY1352-RF) Three Phase Prepaid Energy Meter with RS485 Built-in Magnetic Relay for Acrel IOT Platform Energy Prepayment by Cards

● 3 phase 4 wires ● Rated voltage: 3*220V/380V ● Rated current: 3*1(6)A, or 3*10(80)A ● Prepaid function, support prepayment by cards, remote switch on/off  ● Overload: 1.2 times rating (continuous), 2 times the rating for 1 second            ● Accuracy: Class 0.5S ● Communication: RS485(Modbus-RTU) ● kWh  (positive and negative), kVarh (positive and negative), U, I, P, Q, S, PF, Hz, etc. ● Communication, and other parameters can be programmable by the key ● LCD dispaly: Segmented LCD display ● Active pulse output ● LCD dispaly: Segmented LCD display ● Grid frequency: 45~65Hz, error ±0.5% ● Standard & Certificate: CE;
Learn more

Acrel ADL300-EYNK(DTSY1352-NK) Three Phase Prepaid Energy Meter with RS485 Built-in Magnetic Relay for Acrel IOT Platform Energy Prepayment Online

● Rated voltage: 3*220V/380V ● Rated current: 3*1(6)A, or 3*10(80)A ● Prepaid function, support prepayment by online, remote switch on/off  ● Overload: 1.2 times rating (continuous), 2 times the rating for 1 second            ● Accuracy: Class 0.5S ● Communication: RS485(Modbus-RTU) ● kWh  (positive and negative), kVarh (positive and negative), U, I, P, Q, S, PF, Hz, etc. ● Communication, and other parameters can be programmable by the key ● LCD dispaly: Segmented LCD display ● Active pulse output ● LCD dispaly: Segmented LCD display ● Grid frequency: 45~65Hz, error ±0.5% ● Standard & Certificate: CE;
Learn more

Acrel AMC200-8E3/4G Digital Smart Multi-Circuit AC Power Meter with 4G communication For Tower Base Station Energy Consumption Monitoring

● Funtion:full power parameter measurement, Active 2DI + Passive 4DI + 2DO, 4 NTC Temperature, 1 T&H ● Circuit: 4 or 8 Channels 3 phase or 12 or 24 channels single phase mA class current sensor ● RS485,Modbus RTU protocol ● Power supply: AC/DC 85-265V ● Applicaiton: telecom Base station,other multi channels applicaiton
Learn more

Acrel AMC200-8E3 Digital Smart Multi-Circuit AC Power Meter For Tower Base Station Energy Consumption Monitoring

● Funtion:full power parameter measurement, Active 2DI + Passive 4DI + 2DO, 4 NTC Temperature, 1 T&H ● Circuit: 4 or 8 Channels 3 phase or 12 or 24 channels single phase mA class current sensor ● RS485,Modbus RTU protocol ● Power supply: AC/DC 85-265V ● Applicaiton: telecom Base station,other multi channels applicaiton
Learn more

Acrel AMC200-4E3/4G Digital Smart Multi-Circuit AC Energy Meter with 4G communication For Tower Base Station Energy Consumption Monitoring

● Funtion:full power parameter measurement, Active 2DI + Passive 4DI + 2DO, 4 NTC Temperature, 1 T&H ● Circuit: 4 or 8 Channels 3 phase or 12 or 24 channels single phase mA class current sensor ● RS485,Modbus RTU protocol ● Power supply: AC/DC 85-265V ● Applicaiton: telecom Base station,other multi channels applicaiton
Learn more

Acrel AMC200-4E3 Smart Digital Multi-Circuit AC Energy Meter For Tower Base Station Energy Consumption Monitoring

● Funtion:full power parameter measurement, Active 2DI + Passive 4DI + 2DO, 4 NTC Temperature, 1 T&H ● Circuit: 4 or 8 Channels 3 phase or 12 or 24 channels single phase mA class current sensor ● RS485,Modbus RTU protocol ● Power supply: AC/DC 85-265V ● Applicaiton: telecom Base station,other multi channels applicaiton
Learn more

Acrel AMC200L-8E3/4G Smart Digital Multi-Circuit AC Electricity Meter with 4G Communication For Tower Base Station Energy Consumption Monitoring

● Funtion:full power parameter measurement, Active 2DI + Passive 4DI + 2DO, 4 NTC Temperature, 1 T&H ● Circuit: 4 or 8 Channels 3 phase or 12 or 24 channels single phase mA class current sensor ● RS485(Modbus RTU protocol), 4G ● Power supply: AC/DC 85-265V ● Applicaiton: telecom Base station,other multi channels applicaiton
Learn more

Acrel AMC200L-8E3 Smart Digital Multi-Circuit AC Power Meter For Tower Base Station Energy Consumption Monitoring

● Funtion:full power parameter measurement, Active 2DI + Passive 4DI + 2DO, 4 NTC Temperature, 1 T&H ● Circuit: 4 or 8 Channels 3 phase or 12 or 24 channels single phase mA class current sensor ● RS485,Modbus RTU protocol ● Power supply: AC/DC 85-265V ● Applicaiton: telecom Base station,other multi channels applicaiton
Learn more

Acrel AMC200L-4E3/4G Digital Multi-Circuit AC Electricity Meter with 4G Communication For Tower Base Station Energy Consumption Monitoring

● Funtion:full power parameter measurement, Active 2DI + Passive 4DI + 2DO, 4 NTC Temperature, 1 T&H ● Circuit:4 or 8 Channels 3 phase or 12 or 24 channels single phase mA class current sensor ● RS485(Modbus RTU protocol), 4G ● Power supply: AC/DC 85-265V ● Applicaiton: telecom Base station,other multi channels applicaiton
Learn more

Acrel AMC200L-4E3 Intelligent Digital Multi-Circuit AC Energy Meter For Tower Base Station Energy Consumption Monitoring

● Funtion:full power parameter measurement, Active 2DI + Passive 4DI + 2DO, 4 NTC Temperature, 1 T&H ● Circuit: 4 or 8 Channels 3 phase or 12 or 24 channels single phase mA class current sensor ● RS485,Modbus RTU protocol ● Power supply: AC/DC 85-265V ● Applicaiton: telecom Base station,other multi channels applicaiton
Learn more

Acrel DTSD1352-4S Digital Multi Circuits AC Energy Meter For Tower Base Station Energy Consumption Monitoring

● Rated Current: AC250A, 100A ● Rated Voltage: 3x220V/380V AC (3P4W) ● Measure up to 4 circuit 3 phase ● Measure all electric parameters ● RS485 interface Modbus-RTU communication ● LCD Display; 35mm DIN Rail Installation ● Work with RJ45 port External Split core CTs
Learn more

Acrel ADW600 CE IEC Approved Wireless 4G Digital 3 Phase Multi-channel Energy Meter For IOT Platform Energy Consumption Monitoring

● Measures active kWh (positive and negative), Reactive kWh (positive and negative), U, I, P, Q, S, PF, F, etc. ● Communication: 4G, WiFi, Ethernet, RS485(Modbus-RTU) ● Full electric parameter measurement,Multi Channels independent metering ● With Different Size of CTs,easy to install D10,D16,D24,D36 ● Optional 4DI/2DO,12 channels temp measure,4 channels Residual current monitoring ● Application: for the Multi channels places ● Standard&Certificate: CE; IEC
Learn more

AMC16Z-FDK48 Digital Multi Circuits DC Energy Meter For Data Center Energy Consumption Monitoring

● Designed specifically for the power supply management of server in the data center ● A+B independent 24 circuits(48 in total) ● U, I, P, Q, S, PF, kWh, kvarh ● 2nd-31st Harmonic ● kWh Class 0.5 ● DIN 35 mm
Learn more
< 12 >