Products

PRODUCT CENTER

Click to see the full breakdown
×

Acrel ADL3000-E/C(DTSD1352-C) CE UL Approved Digital 3 Phase Anti-reflux Energy Meter for Solar Power Inverters IOT Platform Energy Consumption Monitoring

● Measures active kWh (positive and negative), Reactive kWh (positive and negative), U, I, P, Q, S, PF, F, etc. ● Communication: RS485(Modbus-RTU), link to IOT Platform ● Harmonic on 2nd-31st ● Multi tariff ● Max demand and and occurrence time ● Frozen data on last 48 months, last 90 days ● Accuracy:Class 0.5S ● Active pulse output ● 12 bits section LCD display, background light ● 3 keys to communication and set parameters ● Rated voltage: 3×100V, 3×380V, 3×57.7/100V, 3×230/400V (withstand 120% load) ● Rated current: 3×1(6)A, 3×10(80)A (withstand 120% load) ● Standard&Certificate: UL; CE; IEC
Learn more

Acrel AGF-M4T CE Approved Digital Multi Loop DC Energy Meter For IOT Platform Solar Power Consumption Monitoring

● Measurement: kWh, U, I, P, Q, S, etc. ● Measures 2 channels of DC energy(optional) ● Measures bidirectional DC energy ● Communication: RS485(Modbus-RTU),2 channels of RS485(optional) ● Communication protocol: Modbus-RTU, DL/T 645-2007 ● Built-in Bipolar Power Source: Power Supply for Hall Effect CT (DC -12V ~ DC +12V) ● Voltage input range: DC0-1000V ● Input signal: Shunt:0-75mV;Hall sensor:0-20mA, 4-20mA, 0-5V, 0-10V and so on. ● 2DI/2DO ● Power supply: AC/DC 85-265V or DC24V(±10%) or DC48V(±10%) ● Accuracy: 1 or 0.5 (connected via shunt)(optional) ● Switch output: 2 Relay outputs, 2A/30VDC or 2A/250VAC ● Switch input: 2 dry contact inputs ● Pulse output: A second pulse output, an energy pulse output ● Display: 8 digits display U, I, P, Q, kWh and other energy consumption ● Average barrier-free working hours: ≥50000h ● Mounted: Din rail 35mm ● Standard & Certificate: CE; IEC; UL
Learn more

Acrel DJSF1352-RN/D CE UL Approved Digital Multi Loop DC Energy Meter For IOT Platform Solar Power Consumption Monitoring

● Measurement: kWh, U, I, P, Q, S, etc. ● Measures 2 channels of DC energy(optional) ● Measures bidirectional DC energy ● Communication: RS485(Modbus-RTU),2 channels of RS485(optional) ● Communication protocol: Modbus-RTU, DL/T 645-2007 ● Built-in Bipolar Power Source: Power Supply for Hall Effect CT (DC -12V ~ DC +12V) ● Voltage input range: DC0-1000V ● Input signal: Shunt:0-75mV;Hall sensor:0-20mA, 4-20mA, 0-5V, 0-10V and so on. ● 2DI/2DO ● Power supply: AC/DC 85-265V or DC24V(±10%) or DC48V(±10%) ● Accuracy: 1 or 0.5 (connected via shunt)(optional) ● Switch output: 2 Relay outputs, 2A/30VDC or 2A/250VAC ● Switch input: 2 dry contact inputs ● Pulse output: A second pulse output, an energy pulse output ● Display: 8 digits display U, I, P, Q, kWh and other energy consumption ● Average barrier-free working hours: ≥50000h ● Mounted: Din rail 35mm ● Standard & Certificate: CE; IEC; UL
Learn more

ADF400L-36D CE Approved Digital Multi-channel Energy Meter Measure 36 channels of Single Phase Circuits 80A 3*80A for IOT Platform Energy Consumption Monitoring

● Application: Prepaid & Postpaid (See Acrel Prepaid Solution) ● Monitoring: Up to 36 Circuits 1-phase or 12 Circuits 3-phase or Mixed ● Measurement: 1-phase&3-phase kWh (Class 0.5S), kVarh, Active Power, Reactive Power, Current, Voltage and etc ● Rated Voltage: 3x220/380V (50Hz) ● Rated Current: 80A AC (direct connection); 3x1(6)A AC (via CTs) ● Communication (Main Body): RS485 (MODBUS-RTU); Ethernet; Infrared ● Communication (Expanded): 4G; WiFi; LoRa ● Remote Control: DO&DI ● Installtion: 35mm DIN Rail ● Power Supply: 3*220/380V or 220V AC ● Standard&Certificate: CE
Learn more

ADF400L-12S CE Approved Digital Multi-Loop Energy Meter Measure 12 channels of 3 Phase Circuits 3*80A for IOT Platform Energy Consumption Monitoring

● Application: Prepaid & Postpaid (See Acrel Prepaid Solution) ● Monitoring: Up to 36 Circuits 1-phase or 12 Circuits 3-phase or Mixed ● Measurement: 1-phase&3-phase kWh (Class 0.5S), kVarh, Active Power, Reactive Power, Current, Voltage and etc ● Rated Voltage: 3x220/380V (50Hz) ● Rated Current: 80A AC (direct connection); 3x1(6)A AC (via CTs) ● Communication (Main Body): RS485 (MODBUS-RTU); Ethernet; Infrared ● Communication (Expanded): 4G; WiFi; LoRa ● Remote Control: DO&DI ● Installtion: 35mm DIN Rail ● Power Supply: 3*220/380V or 220V AC ● Standard&Certificate: CE
Learn more

ADF400L-12H CE Approved Digital Multi Circuits Energy Meter Measure 12 channels of 3 Phase Circuits For IOT Platform Energy Consumption Monitoring

● Application: Prepaid & Postpaid (See Acrel Prepaid Solution) ● Monitoring: Up to 36 Circuits 1-phase or 12 Circuits 3-phase or Mixed ● Measurement: 1-phase&3-phase kWh (Class 0.5S), kVarh, Active Power, Reactive Power, Current, Voltage and etc ● Rated Voltage: 3x220/380V (50Hz) ● Rated Current: 80A AC (direct connection); 3x1(6)A AC (via CTs) ● Communication (Main Body): RS485 (MODBUS-RTU); Ethernet; Infrared ● Communication (Expanded): 4G; WiFi; LoRa ● Remote Control: DO&DI ● Installtion: 35mm DIN Rail ● Power Supply: 3*220/380V or 220V AC ● Standard&Certificate: CE
Learn more

ADF400L-12HY CE Approved Digital Multi Circuits Prepaid Energy Meter Measure 12 channels of 3 Phase Circuits For IOT Platform Energy Consumption Monitoring

● Application: Prepaid & Postpaid (See Acrel Prepaid Solution) ● Monitoring: Up to 36 Circuits 1-phase or 12 Circuits 3-phase or Mixed ● Measurement: 1-phase&3-phase kWh (Class 0.5S), kVarh, Active Power, Reactive Power, Current, Voltage and etc ● Rated Voltage: 3x220/380V (50Hz) ● Rated Current: 80A AC (direct connection); 3x1(6)A AC (via CTs) ● Communication (Main Body): RS485 (MODBUS-RTU); Ethernet; Infrared ● Communication (Expanded): 4G; WiFi; LoRa ● Remote Control: DO&DI ● Installtion: 35mm DIN Rail ● Power Supply: 3*220/380V or 220V AC ● Standard&Certificate: CE
Learn more

ADW220-D16-4S CE Approved Digital Multi Circuits Lora Energy Meter For IOT Platform Energy Consumption Monitoring

● Measures 4 channels of 3 phase circuits ● Measures 3 phase power, total power (active, reactive, apparent), U, I, P, Q, S, PF, F, zero sequence current, voltage/current phase angle, voltage/current degree of unbalance, etc. ● Communication: RS485(Modbus-RTU), LoRa ● Harmonic on 2nd-31st ● Multi tariff: 4 time zones 14Periods rate setting; ● Maximum Current, maximum power demand and real time Current, real time power demand; ● Record of voltage, current and power extreme of current month and last month; ● 200 event records, record the action of DIDO; ● Support over-voltage, over-current, phase failure, DI linkage and other alarm output; ● Accuracy: Class 1 ● 12 channel Switching inputs+4 channel Switching outputs; ● 12 channel external NTC temperature +4 channel residual current measurement (leakage current); ● Rated voltage: 3×220/380V ● Rated current: 5A( secondary transforming), 100A, 400A, 600A.
Learn more

ADW200-D16-4S CE Approved Digital Multi Circuits Energy Meter For IOT Platform Energy Consumption Monitoring

● Measures 4 channels of 3 phase circuits ● Measures 3 phase power, total power (active, reactive, apparent), U, I, P, Q, S, PF, F, zero sequence current, voltage/current phase angle, voltage/current degree of unbalance, etc. ● Communication: RS485(Modbus-RTU) ● Harmonic on 2nd-31st ● Multi tariff: 4 time zones 14Periods rate setting; ● Maximum Current, maximum power demand and real time Current, real time power demand; ● Record of voltage, current and power extreme of current month and last month; ● 200 event records, record the action of DIDO; ● Support over-voltage, over-current, phase failure, DI linkage and other alarm output; ● Accuracy: Class 1 ● 12 channel Switching inputs+4 channel Switching outputs; ● 12 channel external NTC temperature +4 channel residual current measurement (leakage current); ● Rated voltage: 3×220/380V ● Rated current: 5A( secondary transforming), 100A, 400A, 600A.
Learn more

ADW210-D16-4S CE Approved Digital Multi Circuits Energy Meter For IOT Platform Energy Consumption Monitoring

● Measures 4 channels of 3 phase circuits ● Measures 3 phase power, total power (active, reactive, apparent), U, I, P, Q, S, PF, F, zero sequence current, voltage/current phase angle, voltage/current degree of unbalance, etc. ● Communication: RS485(Modbus-RTU) ● Harmonic on 2nd-31st ● Multi tariff: 4 time zones 14Periods rate setting; ● Maximum Current, maximum power demand and real time Current, real time power demand; ● Record of voltage, current and power extreme of current month and last month; ● 200 event records, record the action of DIDO; ● Support over-voltage, over-current, phase failure, DI linkage and other alarm output; ● Accuracy: Class 1 ● 12 channel Switching inputs+4 channel Switching outputs; ● 12 bits section LCD display, background light ● 12 channel external NTC temperature +4 channel residual current measurement (leakage current); ● Rated voltage: 3×220/380V ● Rated current: 5A( secondary transforming), 100A, 400A, 600A.
Learn more

AHKC-EKB 1000A/0-5V Split Core Hall Effect Sensor for DC Energy Meters IOT Platform Energy Consumption Monitoring

● Rated current input:AC/DC0-(200-1000)A ● Rated output voltage: ±5V/±4V, 10V,  2.5V±2V, ±3.3V, 1-5V, 2.5±0.625V ● Aperture: 40mm ● Power supply: ±15V, ±12V ● Accuracy Class: 1 ● Bandwidth: 0~20kHz ● Isolation Voltage: 3.5kV/50Hz/1min ● Operating Temperature: -40℃~85℃ ● Storage Temperature: -40℃~85℃ ● Consumption: ≤0.5W ● Standard&Certificate: CE; IEC; UL
Learn more

AHKC-EKA 500A/0-5V Split Core Hall Effect Sensor for DC Energy Meters IOT Platform Energy Consumption Monitoring

● Rated current input:AC/DC0-(50-500)A ● Rated output voltage: ±5V/±4V, 10V,  2.5V±2V, ±3.3V, 1-5V, 2.5±0.625V ● Aperture: 20mm/40mm/55mm/etc ● Power supply: ±15V, ±12V ● Accuracy Class: 1 ● Bandwidth: 0~20kHz ● Isolation Voltage: 3.5kV/50Hz/1min ● Operating Temperature: -40℃~85℃ ● Storage Temperature: -40℃~85℃ ● Consumption: ≤0.5W ● Standard&Certificate: CE; IEC; UL
Learn more