Acrel ADL100-EYNK/4G (DDSY1352-NK/4G) Single Phase 4G Prepaid Energy Meter with RS485 Built-in Magnetic Relay for Acrel IOT Platform Energy Prepayment Online

● Single phase 2 wires ● Rated voltage: 220V, 230V ● Rated current: 0.1A-60A  ● Prepaid function, support prepayment by online, remote switch on/off  ● Overload: 1.2 times rating (continuous), 2 times the rating for 1 second            ● Accuracy: Class 1 ● Communication: RS485(Modbus-RTU), 4G ● kWh  (positive and negative), kVarh (positive and negative), U, I, P, Q, S, PF, Hz, etc. ● Communication, and other parameters can be programmable by the key ● LCD dispaly: Segmented LCD display ● Active pulse output ● LCD dispaly: Segmented LCD display ● Grid frequency: 45~65Hz, error ±0.5% ● Standard & Certificate: CE;
Learn more

Acrel ADL100-EYNK/WF(DDSY1352-NK/WF) Single Phase WiFi Prepaid Energy Meter with RS485 Built-in Magnetic Relay for Acrel IOT Platform Energy Prepayment Online

● Single phase 2 wires ● Rated voltage: 220V, 230V ● Rated current: 0.1A-60A  ● Prepaid function, support prepayment by online, remote switch on/off  ● Overload: 1.2 times rating (continuous), 2 times the rating for 1 second            ● Accuracy: Class 1 ● Communication: RS485(Modbus-RTU) ● kWh  (positive and negative), kVarh (positive and negative), U, I, P, Q, S, PF, Hz, etc. ● Communication, and other parameters can be programmable by the key ● LCD dispaly: Segmented LCD display ● Active pulse output ● LCD dispaly: Segmented LCD display ● Grid frequency: 45~65Hz, error ±0.5% ● Standard & Certificate: CE;
Learn more

Acrel ADL100-EYZ (DDSY1352-Z) Single Phase Prepaid Energy Meter with RS485 Support Card Prepayment or Prepayment Online Recharge for Acrel IOT Platform Energy Prepayment by Online or by Cards

● Single phase 2 wires ● Rated voltage: 220V, 230V ● Rated current: 0.1A-60A  ● Prepaid function, support prepayment by online or by cards, remote switch on/off  ● Overload: 1.2 times rating (continuous), 2 times the rating for 1 second            ● Accuracy: Class 1 ● Communication: RS485(Modbus-RTU) ● kWh  (positive and negative), kVarh (positive and negative), U, I, P, Q, S, PF, Hz, etc. ● Communication, and other parameters can be programmable by the key ● LCD dispaly: Segmented LCD display ● Active pulse output ● LCD dispaly: Segmented LCD display ● Grid frequency: 45~65Hz, error ±0.5% ● Standard & Certificate: CE;
Learn more

Acrel ADL100-EYRF(DDSY1352-RF) Single Phase Prepaid Energy Meter with RS485 Radio Frequency Card Recharge for Acrel IOT Platform Energy Prepayment by Cards

● Single phase 2 wires ● Rated voltage: 220V, 230V ● Rated current: 0.1A-60A  ● Prepaid function, support prepayment by cards, remote switch on/off  ● Overload: 1.2 times rating (continuous), 2 times the rating for 1 second            ● Accuracy: Class 1 ● Communication: RS485(Modbus-RTU) ● kWh  (positive and negative), kVarh (positive and negative), U, I, P, Q, S, PF, Hz, etc. ● Communication, and other parameters can be programmable by the key ● LCD dispaly: Segmented LCD display ● Active pulse output ● LCD dispaly: Segmented LCD display ● Grid frequency: 45~65Hz, error ±0.5% ● Standard & Certificate: CE;
Learn more

Acrel ADL100-EYNK(DDSY1352-NK) Single Phase Prepaid Energy Meter with RS485 Built-in Magnetic Relay for Acrel IOT Platform Energy Prepayment Online

● Single phase 2 wires ● Rated voltage: 220V, 230V ● Rated current: 0.1A-60A  ● Prepaid function, support prepayment by online, remote switch on/off  ● Overload: 1.2 times rating (continuous), 2 times the rating for 1 second            ● Accuracy: Class 1 ● Communication: RS485(Modbus-RTU) ● kWh  (positive and negative), kVarh (positive and negative), U, I, P, Q, S, PF, Hz, etc. ● Communication, and other parameters can be programmable by the key ● LCD dispaly: Segmented LCD display ● Active pulse output ● LCD dispaly: Segmented LCD display ● Grid frequency: 45~65Hz, error ±0.5% ● Standard & Certificate: CE;
Learn more

Acrel AASCB1-63-C63-4P/ZWiFi WiFi Smart Circuit Breaker for Remote Control Power Monitor Power Consumption

● Real-time monitoring of voltage, current, power, electric energy, temperature, leakage current and other parameters ● With over voltage, under voltage, overload, short circuit, over current, ultra-moderate leakage and other protection functions ● Communication: RS485(Modbus-RTU), 4G ● With local manual lever, local electric control, local lock, remote control, timing control and other control functions ● optional buckle curve type C / D type. ● Guide rail type installation, optional pole number 2P / 4P ● Monitor residual current ● Neutral line can be switch off and protected ● The rated current it can monitor is 16A/32A/63A ● Installation: Din rail installed
Learn more

Acrel AASCB1-63-C63-4P/Z4GHW 4G Smart Circuit Breaker for Remote Control Power Monitor Power Consumption

● Real-time monitoring of voltage, current, power, electric energy, temperature, leakage current and other parameters ● With over voltage, under voltage, overload, short circuit, over current, ultra-moderate leakage and other protection functions ● Communication: RS485(Modbus-RTU), 4G ● With local manual lever, local electric control, local lock, remote control, timing control and other control functions ● optional buckle curve type C / D type. ● Guide rail type installation, optional pole number 2P / 4P ● Monitor residual current ● Neutral line can be switch off and protected ● The rated current it can monitor is 16A/32A/63A ● Installation: Din rail installed
Learn more

Acrel AASCB1-63-C32-2P/ZWiFi WiFi Smart Circuit Breaker for Remote Control Power Monitor Power Consumption

● Real-time monitoring of voltage, current, power, electric energy, temperature, leakage current and other parameters ● With over voltage, under voltage, overload, short circuit, over current, ultra-moderate leakage and other protection functions ● Communication: RS485(Modbus-RTU), 4G ● With local manual lever, local electric control, local lock, remote control, timing control and other control functions ● optional buckle curve type C / D type. ● Guide rail type installation, optional pole number 2P / 4P ● Monitor residual current ● Neutral line can be switch off and protected ● The rated current it can monitor is 16A/32A/63A ● Installation: Din rail installed
Learn more

Acrel AASCB1-63-C16-2P/Z4GHW 4G Smart Circuit Breaker for Remote Control Power Monitor Power Consumption

● Real-time monitoring of voltage, current, power, electric energy, temperature, leakage current and other parameters ● With over voltage, under voltage, overload, short circuit, over current, ultra-moderate leakage and other protection functions ● Communication: RS485(Modbus-RTU), 4G ● With local manual lever, local electric control, local lock, remote control, timing control and other control functions ● optional buckle curve type C / D type. ● Guide rail type installation, optional pole number 2P / 4P ● Monitor residual current ● Neutral line can be switch off and protected ● The rated current it can monitor is 16A/32A/63A ● Installation: Din rail installed
Learn more

Acrel ASCB1-MS-4GUE Smart 4G Gateway for Smart Circuit Breaker for Remote Control Power Monitor Residual Current

● Real-time monitoring of voltage, current, power, electric energy, temperature, leakage current and other parameters ● With over voltage, under voltage, overload, short circuit, over current, ultra-moderate leakage and other protection functions ● Communication: RS485(Modbus-RTU) ● With local manual lever, local electric control, local lock, remote control, timing control and other control functions ● optional buckle curve type C / D type. ● Guide rail type installation, optional pole number 1P / 2P / 3P / 4P ● Monitor residual current ● Neutral line can be switch off and protected ● The rated current it can monitor is 63A ● Installation: Din rail installed
Learn more

Acrel ASCB1-MS-CE Smart Ethernet Gateway for Smart Circuit Breaker for Remote Control Power Monitor Residual Current

● Real-time monitoring of voltage, current, power, electric energy, temperature, leakage current and other parameters ● With over voltage, under voltage, overload, short circuit, over current, ultra-moderate leakage and other protection functions ● Communication: RS485(Modbus-RTU) ● With local manual lever, local electric control, local lock, remote control, timing control and other control functions ● optional buckle curve type C / D type. ● Guide rail type installation, optional pole number 1P / 2P / 3P / 4P ● Monitor residual current ● Neutral line can be switch off and protected ● The rated current it can monitor is 63A ● Installation: Din rail installed
Learn more

Acrel ASCB1-MS-WF Smart WiFi Gateway for Smart Circuit Breaker for Remote Control Power Monitor Residual Current

● Real-time monitoring of voltage, current, power, electric energy, temperature, leakage current and other parameters ● With over voltage, under voltage, overload, short circuit, over current, ultra-moderate leakage and other protection functions ● Communication: RS485(Modbus-RTU) ● With local manual lever, local electric control, local lock, remote control, timing control and other control functions ● optional buckle curve type C / D type. ● Guide rail type installation, optional pole number 1P / 2P / 3P / 4P ● Monitor residual current ● Neutral line can be switch off and protected ● The rated current it can monitor is 63A ● Installation: Din rail installed
Learn more

Acrel ASCB1LE-63-C63-4P Electrical Din Rail 63A Smart Three Phase Circuit Breaker for Remote Control Power Monitor Residual Current, Neutral Line Can be Switch off and Protected

● Real-time monitoring of voltage, current, power, electric energy, temperature, leakage current and other parameters ● With over voltage, under voltage, overload, short circuit, over current, ultra-moderate leakage and other protection functions ● Communication: RS485(Modbus-RTU) ● With local manual lever, local electric control, local lock, remote control, timing control and other control functions ● optional buckle curve type C / D type. ● Guide rail type installation, optional pole number 1P / 2P / 3P / 4P ● Monitor residual current ● Neutral line can be switch off and protected ● The rated current it can monitor is 63A ● Installation: Din rail installed
Learn more

Acrel ASCB1LE-63-C32-4P Electrical Din Rail 32A Smart Three Phase Circuit Breaker for Remote Control Power Monitor Residual Current, Neutral Line Can be Switch off and Protected

● Real-time monitoring of voltage, current, power, electric energy, temperature, leakage current and other parameters ● With over voltage, under voltage, overload, short circuit, over current, ultra-moderate leakage and other protection functions ● Communication: RS485(Modbus-RTU) ● With local manual lever, local electric control, local lock, remote control, timing control and other control functions ● optional buckle curve type C / D type. ● Guide rail type installation, optional pole number 1P / 2P / 3P / 4P ● Monitor residual current ● Neutral line can be switch off and protected ● The rated current it can monitor is 63A ● Installation: Din rail installed
Learn more

Acrel ASCB1LE-63-C16-4P Electrical Din Rail 16A Smart Three Phase Circuit Breaker for Remote Control Power Monitor Residual Current, Neutral Line Can be Switch off and Protected

● Real-time monitoring of voltage, current, power, electric energy, temperature, leakage current and other parameters ● With over voltage, under voltage, overload, short circuit, over current, ultra-moderate leakage and other protection functions ● Communication: RS485(Modbus-RTU) ● With local manual lever, local electric control, local lock, remote control, timing control and other control functions ● optional buckle curve type C / D type. ● Guide rail type installation, optional pole number 1P / 2P / 3P / 4P ● Monitor residual current ● Neutral line can be switch off and protected ● The rated current it can monitor is 63A ● Installation: Din rail installed
Learn more

Acrel ASCB1-63-C63-4P Electrical Din Rail 63A Smart Three Phase Circuit Breaker for Remote Control Power Consumption Monitoring

● Real-time monitoring of voltage, current, power, electric energy, temperature, leakage current and other parameters ● With over voltage, under voltage, overload, short circuit, over current, ultra-moderate leakage and other protection functions ● Communication: RS485(Modbus-RTU) ● With local manual lever, local electric control, local lock, remote control, timing control and other control functions ● optional buckle curve type C / D type. ● Guide rail type installation, optional pole number 1P / 2P / 3P / 4P ● Monitor residual current ● Neutral line can be switch off and protected ● The rated current it can monitor is 63A ● Installation: Din rail installed
Learn more

Acrel ASCB1-63-C32-4P Electrical Din Rail 32A Smart Three Phase Circuit Breaker for Remote Control Power Consumption Monitoring

● Real-time monitoring of voltage, current, power, electric energy, temperature, leakage current and other parameters ● With over voltage, under voltage, overload, short circuit, over current, ultra-moderate leakage and other protection functions ● Communication: RS485(Modbus-RTU) ● With local manual lever, local electric control, local lock, remote control, timing control and other control functions ● optional buckle curve type C / D type. ● Guide rail type installation, optional pole number 1P / 2P / 3P / 4P ● Monitor residual current ● Neutral line can be switch off and protected ● The rated current it can monitor is 63A ● Installation: Din rail installed
Learn more

Acrel ASCB1-63-C16-4P Electrical Din Rail 16A Smart Three Phase Circuit Breaker for Remote Control Power Consumption Monitoring

● Real-time monitoring of voltage, current, power, electric energy, temperature, leakage current and other parameters ● With over voltage, under voltage, overload, short circuit, over current, ultra-moderate leakage and other protection functions ● Communication: RS485(Modbus-RTU) ● With local manual lever, local electric control, local lock, remote control, timing control and other control functions ● optional buckle curve type C / D type. ● Guide rail type installation, optional pole number 1P / 2P / 3P / 4P ● Monitor residual current ● Neutral line can be switch off and protected ● The rated current it can monitor is 63A ● Installation: Din rail installed
Learn more

Acrel ASCB1-63-C63-3P Electrical Din Rail 63A Smart Three Phase Circuit Breaker for Remote Control Power Consumption Monitoring

● Real-time monitoring of voltage, current, power, electric energy, temperature, leakage current and other parameters ● With over voltage, under voltage, overload, short circuit, over current, ultra-moderate leakage and other protection functions ● Communication: RS485(Modbus-RTU) ● With local manual lever, local electric control, local lock, remote control, timing control and other control functions ● optional buckle curve type C / D type. ● Guide rail type installation, optional pole number 1P / 2P / 3P / 4P ● Monitor residual current ● Neutral line can be switch off and protected ● The rated current it can monitor is 63A ● Installation: Din rail installed
Learn more

Acrel ASCB1-63-C32-3P Electrical Din Rail 32A Smart Three Phase Circuit Breaker for Remote Control Power Consumption Monitoring

● Real-time monitoring of voltage, current, power, electric energy, temperature, leakage current and other parameters ● With over voltage, under voltage, overload, short circuit, over current, ultra-moderate leakage and other protection functions ● Communication: RS485(Modbus-RTU) ● With local manual lever, local electric control, local lock, remote control, timing control and other control functions ● optional buckle curve type C / D type. ● Guide rail type installation, optional pole number 1P / 2P / 3P / 4P ● Monitor residual current ● Neutral line can be switch off and protected ● The rated current it can monitor is 63A ● Installation: Din rail installed
Learn more

Acrel ASCB1-63-C16-3P Electrical Din Rail 16A Smart Three Phase Circuit Breaker for Remote Control Power Consumption Monitoring

● Real-time monitoring of voltage, current, power, electric energy, temperature, leakage current and other parameters ● With over voltage, under voltage, overload, short circuit, over current, ultra-moderate leakage and other protection functions ● Communication: RS485(Modbus-RTU) ● With local manual lever, local electric control, local lock, remote control, timing control and other control functions ● optional buckle curve type C / D type. ● Guide rail type installation, optional pole number 1P / 2P / 3P / 4P ● Monitor residual current ● Neutral line can be switch off and protected ● The rated current it can monitor is 63A ● Installation: Din rail installed
Learn more

Acrel ASCB1-63-C63-2P Electrical Din Rail 63A Smart Single Phase Circuit Breaker for Remote Control Power Consumption Monitoring

● Real-time monitoring of voltage, current, power, electric energy, temperature, leakage current and other parameters ● With over voltage, under voltage, overload, short circuit, over current, ultra-moderate leakage and other protection functions ● Communication: RS485(Modbus-RTU) ● With local manual lever, local electric control, local lock, remote control, timing control and other control functions ● optional buckle curve type C / D type. ● Guide rail type installation, optional pole number 1P / 2P / 3P / 4P ● Monitor residual current ● Neutral line can be switch off and protected ● The rated current it can monitor is 63A ● Installation: Din rail installed
Learn more

Acrel ASCB1-63-C32-2P Electrical Din Rail 32A Smart Single Phase Circuit Breaker for Remote Control Power Consumption Monitoring

● Real-time monitoring of voltage, current, power, electric energy, temperature, leakage current and other parameters ● With over voltage, under voltage, overload, short circuit, over current, ultra-moderate leakage and other protection functions ● Communication: RS485(Modbus-RTU) ● With local manual lever, local electric control, local lock, remote control, timing control and other control functions ● optional buckle curve type C / D type. ● Guide rail type installation, optional pole number 1P / 2P / 3P / 4P ● Monitor residual current ● Neutral line can be switch off and protected ● The rated current it can monitor is 63A ● Installation: Din rail installed
Learn more

Acrel ASCB1-63-C16-2P Electrical Din Rail 16A Smart Single Phase Circuit Breaker for Remote Control Power Consumption Monitoring

● Real-time monitoring of voltage, current, power, electric energy, temperature, leakage current and other parameters ● With over voltage, under voltage, overload, short circuit, over current, ultra-moderate leakage and other protection functions ● Communication: RS485(Modbus-RTU) ● With local manual lever, local electric control, local lock, remote control, timing control and other control functions ● optional buckle curve type C / D type. ● Guide rail type installation, optional pole number 1P / 2P / 3P / 4P ● Monitor residual current ● Neutral line can be switch off and protected ● The rated current it can monitor is 63A ● Installation: Din rail installed