PRODUCT CENTER
Click to see the full breakdown
×
Acrel AWT100-4GHW CE Approved 4G Smart Gateway For IOT Platform Energy Consumption Monitoring
● Upstream Methods: 4G LTE (Support Global Frequency Bands)
● Upstream Protocol: MODBUS-TCP, MQTT
● Downstream Methods: RS485 Interface
● Downstream Protocol: MODBUS-RTU
● Support: Up to 20~25 Acrel Devices with RS485 (MODBUS-RTU)
● Power Supply: 24Vdc (default); 85~265Vac/Vdc (via AWT100-POW Module)
● Standard&Certificate: CE-RED; IEC; LVD; EMC
Learn more
● Measurement: Alternating Current (AC)
● Installtion: Split-core type/clamp on installation
● Primary Current Input: 100~400A AC
● Secondary Current Input: (20-100)mA
● Accuracy: Class 0.5
● Rated Operating Voltage: 660V AC
● Rated Frequency: 50~60Hz
● Operating Temperature: -30℃~+70℃
● Operating Altitude: ≤3000m
● Power Frequency withstand Voltage: 3000V/1min 50Hz
● Standard&Certificate: UL, CE
Learn more
● Measurement: Alternating Current (AC)
● Installtion: Split-core type/clamp on installation
● Primary Current Input: 100~400A AC
● Secondary Current Input: (20-100)mA
● Accuracy: Class 0.5
● Rated Operating Voltage: 660V AC
● Rated Frequency: 50~60Hz
● Operating Temperature: -30℃~+70℃
● Operating Altitude: ≤3000m
● Power Frequency withstand Voltage: 3000V/1min 50Hz
● Standard&Certificate: UL, CE
Learn more
● Measurement: Alternating Current (AC)
● Installtion: Split-core type/clamp on installation
● Primary Current Input: 20~120A AC
● Secondary Current Input: 100~333mV
● Accuracy: Class 0.5
● Rated Operating Voltage: 660V AC
● Rated Frequency: 50~60Hz
● Operating Temperature: -30℃~+70℃
● Operating Altitude: ≤3000m
● Power Frequency withstand Voltage: 3000V/1min 50Hz
● Standard&Certificate: UL, CE
Learn more
● Measurement: Alternating Current (AC)
● Installtion: Split-core type/clamp on installation
● Primary Current Input: 20~120A AC
● Secondary Current Input: (10-50)mA
● Accuracy: Class 0.5
● Rated Operating Voltage: 660V AC
● Rated Frequency: 50~60Hz
● Operating Temperature: -30℃~+70℃
● Operating Altitude: ≤3000m
● Power Frequency withstand Voltage: 3000V/1min 50Hz
● Standard&Certificate: UL, CE
Learn more
Acrel DJSF1352-RN-2/S Digital DC Energy Meter For Charging Piles EV Chargers
● Shunt: 0-75mV
● Hall sensor: 0-5V, 0-200mA
● Rated Voltage: DC 0-100V、DC 0-1000V
● Communication: RS485(Modbus-RTU)
● Accuracy Class: 0.5
● Mounted: Din rail 35mm
● Standard & Certificate: CE; IEC;
Learn more
● Suitable for Power Distribution System in Group 2 Medical Location
● Using Q235A Cold Rolled Steel Plate
● Cooling Fan
● Various installation types
● IP31 Protection Level
● IEC60364-7-710:2016; IEC 61439-2:2011
Learn more
● 3 phase 4 wire, 3 phase 3 wire, single phase 3 wire
● Rated voltage: 3×230/400V、3×277/480V;
● Rated current: 3×80A, 3×120A, 3×200A, 3×300A
● Overload: 1.2 times rating (continuous)
2 times the rating for 1 second
● Accuracy: 0.5
● Accuracy of active energy:Class B (split current transformer) /Class C (closed current transformer)
● Communication: RS485(Modbus-RTU)
● kWh (positive and negative)
● kVarh (positive and negative)
● U, I, P, Q, S, PF, Hz, etc.
● Communication, transformation ratio and other parameters can be programmable by the key
● LCD dispaly: Segmented LCD display
● Active pulse output
● LED alarm: Operation instructions
● Grid frequency: 45~65Hz, error ±0.5%
● Standard&Certificate: MID; CE;
Learn more
● 3 phase 4 wire, 3 phase 3 wire, single phase 3 wire
● Rated voltage: 3×230/400V、3×277/480V;
● Rated current: 3×80A, 3×120A, 3×200A, 3×300A
● Overload: 1.2 times rating (continuous)
2 times the rating for 1 second
● Accuracy: 0.5
● Accuracy of active energy:Class B (split current transformer) /Class C (closed current transformer)
● Communication: RS485(Modbus-RTU)
● kWh (positive and negative)
● kVarh (positive and negative)
● U, I, P, Q, S, PF, Hz, etc.
● Communication, transformation ratio and other parameters can be programmable by the key
● LCD dispaly: Segmented LCD display
● Active pulse output
● LED alarm: Operation instructions
● Grid frequency: 45~65Hz, error ±0.5%
● Standard&Certificate: MID; CE;
Learn more
● 3 phase 4 wire, 3 phase 3 wire, single phase 3 wire
● Rated voltage: 3×230/400V、3×277/480V;
● Rated current: 3×80A, 3×120A, 3×200A, 3×300A
● Overload: 1.2 times rating (continuous)
2 times the rating for 1 second
● Accuracy: 0.5
● Accuracy of active energy:Class B (split current transformer) /Class C (closed current transformer)
● Communication: RS485(Modbus-RTU)
● kWh (positive and negative)
● kVarh (positive and negative)
● U, I, P, Q, S, PF, Hz, etc.
● Communication, transformation ratio and other parameters can be programmable by the key
● LCD dispaly: Segmented LCD display
● Active pulse output
● LED alarm: Operation instructions
● Grid frequency: 45~65Hz, error ±0.5%
● Standard&Certificate: MID; CE;
Learn more
● Single phase 2 wires
● Rated voltage: AC 230V;
● Rated current: 80A, 120A, 200A, 300A
● Overload: 1.2 times rating (continuous)
2 times the rating for 1 second
● Accuracy: 0.5
● Accuracy of active energy:Class B (split current transformer) /Class C (closed current transformer)
● Communication: RS485(Modbus-RTU)
● kWh (positive and negative)
● kVarh (positive and negative)
● U, I, P, Q, S, PF, Hz, etc.
● Communication, transformation ratio and other parameters can be programmable by the key
● LCD dispaly: Segmented LCD display
● Active pulse output
● LED alarm: Operation instructions
● Grid frequency: 45~65Hz, error ±0.5%
● Standard&Certificate: MID; CE;
Learn more
● Single phase 2 wires
● Rated voltage: AC 230V;
● Rated current: 80A, 120A, 200A, 300A
● Overload: 1.2 times rating (continuous)
2 times the rating for 1 second
● Accuracy: 0.5
● Accuracy of active energy:Class B (split current transformer) /Class C (closed current transformer)
● Communication: RS485(Modbus-RTU)
● kWh (positive and negative)
● kVarh (positive and negative)
● U, I, P, Q, S, PF, Hz, etc.
● Communication, transformation ratio and other parameters can be programmable by the key
● LCD dispaly: Segmented LCD display
● Active pulse output
● LED alarm: Operation instructions
● Grid frequency: 45~65Hz, error ±0.5%
● Standard&Certificate: MID; CE;
Learn more
● Single phase 2 wires
● Rated voltage: AC 230V;
● Rated current: 80A, 120A, 200A, 300A
● Overload: 1.2 times rating (continuous)
2 times the rating for 1 second
● Accuracy: 0.5
● Accuracy of active energy:Class B (split current transformer) /Class C (closed current transformer)
● Communication: RS485(Modbus-RTU)
● kWh (positive and negative)
● kVarh (positive and negative)
● U, I, P, Q, S, PF, Hz, etc.
● Communication, transformation ratio and other parameters can be programmable by the key
● LCD dispaly: Segmented LCD display
● Active pulse output
● LED alarm: Operation instructions
● Grid frequency: 45~65Hz, error ±0.5%
● Standard&Certificate: MID; CE;
Learn more
● 3 phase 4 wire, 3 phase 3 wire, single phase 3 wire
● Rated voltage: 3×230/400V、3×277/480V;
● Rated current: 3×80A, 3×120A, 3×200A, 3×300A
● Overload: 1.2 times rating (continuous)
2 times the rating for 1 second
● Accuracy: 0.5
● Accuracy of active energy:Class B (split current transformer) /Class C (closed current transformer)
● Communication: RS485(Modbus-RTU)
● kWh (positive and negative)
● kVarh (positive and negative)
● U, I, P, Q, S, PF, Hz, etc.
● Communication, transformation ratio and other parameters can be programmable by the key
● LCD dispaly: Segmented LCD display
● Active pulse output
● LED alarm: Operation instructions
● Grid frequency: 45~65Hz, error ±0.5%
● Standard&Certificate: MID; CE;
Learn more
● Single phase 2 wires
● Rated voltage: AC 230V;
● Rated current: 80A, 120A, 200A, 300A
● Overload: 1.2 times rating (continuous)
2 times the rating for 1 second
● Accuracy: 0.5
● Accuracy of active energy:Class B (split current transformer) /Class C (closed current transformer)
● Communication: RS485(Modbus-RTU)
● kWh (positive and negative)
● kVarh (positive and negative)
● U, I, P, Q, S, PF, Hz, etc.
● Communication, transformation ratio and other parameters can be programmable by the key
● LCD dispaly: Segmented LCD display
● Active pulse output
● LED alarm: Operation instructions
● Grid frequency: 45~65Hz, error ±0.5%
● Standard&Certificate: MID; CE;
Learn more
● Measures active kWh (positive and negative), Reactive kWh (positive and negative), U, I, P, Q, S, PF, F, etc.
● Communication: RS485(Modbus-RTU), link to IOT Platform
● Harmonic on 2nd-31st
● Multi tariff
● Max demand and and occurrence time
● Frozen data on last 48 months, last 90 days
● Accuracy:Class 0.5S
● Active pulse output
● 12 bits section LCD display, background light
● 3 keys to communication and set parameters
● Rated voltage: 3×100V, 3×380V, 3×57.7/100V, 3×240/415V (withstand 120% load)
● Rated current: 3×1(6)A, 3×10(100)A (withstand 120% load)
● Standard&Certificate: UL; CE; IEC
Learn more
● Real-time monitoring of voltage, current, power, electric energy, temperature, leakage current and other parameters
● With over voltage, under voltage, overload, short circuit, over current, ultra-moderate leakage and other protection functions
● Communication: RS485(Modbus-RTU)
● With local manual lever, local electric control, local lock, remote control, timing control and other control functions
● optional buckle curve type C / D type.
● Guide rail type installation, optional pole number 1P / 2P / 3P / 4P
● Monitor residual current
● Neutral line can be switch off and protected
● The rated current it can monitor is 63A
● Installation: Din rail installed
Learn more
● Real-time monitoring of voltage, current, power, electric energy, temperature, leakage current and other parameters
● With over voltage, under voltage, overload, short circuit, over current, ultra-moderate leakage and other protection functions
● Communication: RS485(Modbus-RTU)
● With local manual lever, local electric control, local lock, remote control, timing control and other control functions
● optional buckle curve type C / D type.
● Guide rail type installation, optional pole number 1P / 2P / 3P / 4P
● Monitor residual current
● Neutral line can be switch off and protected
● The rated current it can monitor is 32A
● Installation: Din rail installed
Learn more
● Measures active kWh (positive and negative), Reactive kWh (positive and negative), U, I, P, Q, S, PF, F, etc.
● Communication: 4G, WiFi, LoRa, LoRaWAN, RS485(Modbus-RTU)
● Harmonic on 2nd-31st
● 4DI+2DO
● Measure 1 way of residual current
● Monitor 4 cables' temperature
● Power failure alarm, 2DI/2DO
● Multi tariff
● Max demand and and occurrence time
● Frozen data on last 48 months, last 90 days
● Accuracy:Class 0.5
● Active pulse output
● 12 bits section LCD display, background light
● 3 keys to communication and set parameters
● Rated voltage: 3×57.7/100V,3×220/380V,3×380/660V,3×100V, 3×380V,3×660V
● Rated current: 3×1(6)A
● Standard&Certificate: CE; IEC
Learn more
● Measures active kWh (positive and negative), Reactive kWh (positive and negative), U, I, P, Q, S, PF, F, etc.
● Communication: RS485(Modbus-RTU), link to IOT Platform
● Harmonic on 2nd-31st
● Multi tariff
● Max demand and and occurrence time
● Frozen data on last 48 months, last 90 days
● Accuracy:Class 0.5S
● Active pulse output
● 12 bits section LCD display, background light
● 3 keys to communication and set parameters
● Rated voltage: 3×100V, 3×380V, 3×57.7/100V, 3×230/400V (withstand 120% load)
● Rated current: 3×1(6)A, 3×10(80)A (withstand 120% load)
● Standard&Certificate: MID; CE; IEC
Learn more
● Measures active kWh (positive and negative), Reactive kWh (positive and negative), U, I, P, Q, S, PF, F, etc.
● Communication: RS485(Modbus-RTU), link to IOT Platform
● Harmonic on 2nd-31st
● Multi tariff
● Max demand and and occurrence time
● Frozen data on last 48 months, last 90 days
● Accuracy:Class 0.5S
● Active pulse output
● 12 bits section LCD display, background light
● 3 keys to communication and set parameters
● Rated voltage: 3×100V, 3×380V, 3×57.7/100V, 3×230/400V (withstand 120% load)
● Rated current: 3×1(6)A, 3×10(80)A (withstand 120% load)
● Standard&Certificate: UL; CE; IEC
Learn more
● Primary current is connected in through perforation. Easy installation, high safety.
● With Hall sensor, the max isolation measuring current 20A
● Voltage measurement range for Bus bar is up to DC1.5kV
● LED display, fit for checking and testing operation in wide-temperature or outside environment.
● With the function of inner temperature measurement for real-time measurement of the inner temperature of combiner box
● With RS485 Modbus RTU
● More options of power supply
● Compatible with din rail installation and baseboard fixation installation, small dimension saving more box space.
● Photovoltaic cell open circuit alarm to cooperate with group string voltage and judge Comprehensively
● With 3-channel switching state monitoring to collect output idle contact information of DC breaker 、lightning protector, etc.
● Option RS485 port, Modbus-RTU protocol; programmable slave address, baud rate, data format
● English LCD display,convenient to set parameters and check the data
● Mounted: Din rail 35mm
● Standard & Certificate: CE; IEC;
Learn more