Products

PRODUCT CENTER

Click to see the full breakdown
×

Acrel AMC200L-8E3 Smart Digital Multi-Circuit AC Power Meter For Tower Base Station Energy Consumption Monitoring

● Funtion:full power parameter measurement, Active 2DI + Passive 4DI + 2DO, 4 NTC Temperature, 1 T&H ● Circuit: 4 or 8 Channels 3 phase or 12 or 24 channels single phase mA class current sensor ● RS485,Modbus RTU protocol ● Power supply: AC/DC 85-265V ● Applicaiton: telecom Base station,other multi channels applicaiton
Learn more

Acrel AMC200L-4E3/4G Digital Multi-Circuit AC Electricity Meter with 4G Communication For Tower Base Station Energy Consumption Monitoring

● Funtion:full power parameter measurement, Active 2DI + Passive 4DI + 2DO, 4 NTC Temperature, 1 T&H ● Circuit:4 or 8 Channels 3 phase or 12 or 24 channels single phase mA class current sensor ● RS485(Modbus RTU protocol), 4G ● Power supply: AC/DC 85-265V ● Applicaiton: telecom Base station,other multi channels applicaiton
Learn more

Acrel AMC200L-4E3 Intelligent Digital Multi-Circuit AC Energy Meter For Tower Base Station Energy Consumption Monitoring

● Funtion:full power parameter measurement, Active 2DI + Passive 4DI + 2DO, 4 NTC Temperature, 1 T&H ● Circuit: 4 or 8 Channels 3 phase or 12 or 24 channels single phase mA class current sensor ● RS485,Modbus RTU protocol ● Power supply: AC/DC 85-265V ● Applicaiton: telecom Base station,other multi channels applicaiton
Learn more

Acrel DTSD1352-4S Digital Multi Circuits AC Energy Meter For Tower Base Station Energy Consumption Monitoring

● Rated Current: AC250A, 100A ● Rated Voltage: 3x220V/380V AC (3P4W) ● Measure up to 4 circuit 3 phase ● Measure all electric parameters ● RS485 interface Modbus-RTU communication ● LCD Display; 35mm DIN Rail Installation ● Work with RJ45 port External Split core CTs
Learn more

Acrel AWT200-1E4SL-4GHW CE Approved 4 RS485(Modbus-RTU) / Ethernet & 4G Smart 4G Gateway For IOT Platform Energy Consumption Monitoring

● Upstream Methods: Ethernet(Modbus-TCP/IP), 4G ● Upstream Protocol: MODBUS-TCP/IP, MQTT ● Downstream Methods: RS485 Interface ● Downstream Protocol: MODBUS-RTU ● Support: Up to 100 Acrel Devices with RS485 (MODBUS-RTU) ● Power Supply: 24Vdc (default); 85~265Vac/Vdc (via AWT100-POW Module) ● Standard&Certificate: CE-RED; IEC; LVD; EMC
Learn more

Acrel APView400 Power Quality Monitor Device

● 4 channels of AC voltage; ● 4 channels of AC current; ● 5 DO, 5 DI; ● 2 RS485, support the Modbus-RTU protocol and IRIG-B; ● 2 Ethernet port, support Modbus-TCP、IEC61850 MMS、FTP and device update ; ● 1 USB,used for device updates; ● Standard & Certificate: CE; IEC, etc.
Learn more

Acrel AWT200-1E4SL-WiFi CE Approved 4 RS485(Modbus-RTU) / Ethernet & WiFi Smart WiFi Gateway For IOT Platform Energy Consumption Monitoring

● Upstream Methods: Ethernet(Modbus-TCP/IP), WiFi ● Upstream Protocol: MODBUS-TCP/IP, MQTT ● Downstream Methods: RS485 Interface ● Downstream Protocol: MODBUS-RTU ● Support: Up to 100 Acrel Devices with RS485 (MODBUS-RTU) ● Power Supply: 24Vdc (default); 85~265Vac/Vdc (via AWT100-POW Module) ● Standard&Certificate: CE-RED; IEC; LVD; EMC
Learn more

Acrel ADW600 CE IEC Approved Wireless 4G Digital 3 Phase Multi-channel Energy Meter For IOT Platform Energy Consumption Monitoring

● Measures active kWh (positive and negative), Reactive kWh (positive and negative), U, I, P, Q, S, PF, F, etc. ● Communication: 4G, WiFi, Ethernet, RS485(Modbus-RTU) ● Full electric parameter measurement,Multi Channels independent metering ● With Different Size of CTs,easy to install D10,D16,D24,D36 ● Optional 4DI/2DO,12 channels temp measure,4 channels Residual current monitoring ● Application: for the Multi channels places ● Standard&Certificate: CE; IEC
Learn more

Acrel AWT200-1E4SL CE Approved 4 RS485(Modbus-RTU) / Ethernet Smart Gateway For IOT Platform Energy Consumption Monitoring

● Upstream Methods: Ethernet(Modbus-TCP/IP) ● Upstream Protocol: MODBUS-TCP/IP, MQTT ● Downstream Methods: RS485 Interface ● Downstream Protocol: MODBUS-RTU ● Support: Up to 100 Acrel Devices with RS485 (MODBUS-RTU) ● Power Supply: 24Vdc (default); 85~265Vac/Vdc (via AWT100-POW Module) ● Standard&Certificate: CE-RED; IEC; LVD; EMC
Learn more

Acrel AIM-T500L Industrial Insulation monitoring instrument

● Can monitor AC,DC or AC/DC under 690V mixed ungrounded system ● DC ungrounded system under 800V to ground resistance and capacitance value ● With fault warning and alarm function ● Fault location function ● 1 channel RS485 ● 1 CAN communication ● 2 replay outputs ● Self-check function ● LCD display ● SOE event record
Learn more

Acrel AIM-T500 Industrial Insulation monitoring instrument

● Can monitor AC,DC or AC/DC under 690V mixed ungrounded system ● With fault warning and alarm function ● Connection monitoring of PE and IT systems. ● 1 channel RS485 ● 2 replay outputs ● Self-check function ● LCD display ● SOE event record
Learn more

Acrel AIM-T300 Industrial Insulation monitoring instrument

● AC, DC main circuits ● AC/DC main circuits with directly connected DC components, such as rectifiers ● Systems with switch-mode power supplies
Learn more

ARD2F CE Approved Smart Motor Protectors for Protecting Motors and Power Monitoring

● U, I, P, S, PF, F, EP, Leakage, PTC/NTC ● Start control function ● 8 programmable DI ● 5 programmable DO ● Modbus-RTU or Profibus-DP communication ● 1 DC4-20mA analog output ● SOE ● Anti-shaking function ● Standard&Certificate: CE
Learn more

ARD2M CE Approved Smart Motor Protectors for Protecting Motors and Power Monitoring

● U, I, P, S, PF, F, EP, Leakage, PTC/NTC ● Start control function ● 8 programmable DI ● 5 programmable DO ● Modbus-RTU or Profibus-DP communication ● 1 DC4-20mA analog output ● SOE ● Anti-shaking function ● Standard&Certificate: CE
Learn more

Acrel AM6 Protection Relay Microcomputer Protection Device

● A complete set of protection, related to the application; ● 8 current input, 6 voltage input, 20 DI, 10DO; ● Circuit breaker operating circuit,adaptive 0.25 ~ 5A switching current; ● Auxiliary power supply adapts with AC220V, DC220V, DC110V, AC110V; ● 2 RS485 serial communication, IEC60870-5-103 and Modbus-RTU; ● 2 Ethernet interface,TCP IEC60870-5-103 and TCP Modbus-RTU; ● 2 4-20mAAO channels; ● 2 DC measurement channels. ● 1 GPS for GPS timing,1 USB interface,1 RS232 interface; ● more than 200 sequence of event records, more than 400 system logs, and more than 10 seconds tripping context records; ● Powerful graphic programmable Logic; ● Standard & Certificate: CE; IEC
Learn more

Acrel AM5SE Protection Relay Microcomputer Protection Device

● A complete set of protection, related to the application; ● 8 current input, 4 voltage input, 16 DI, 10 DO; ● Auxiliary power supply adapts with AC220V, DC220V, DC110V, AC110V; ● 2 RS485 serial communication, IEC 60870-5-101, IEC60870-5-103 and Modbus-RTU; ● 1 RS232 for user update; ● 1 GPS for GPS timing; ● More than 200 sequence of event records, more than 400 system logs, and more than 10 seconds tripping context records; ● Powerful graphic programmable Logic. ● Standard & Certificate: CE; IEC
Learn more

Acrel AM4 Protection Relay Microcomputer Protection Device

● Measure current, voltage ● 12DI, 5DO ● over current protection (three stage, inverse time ) ● Over zero-current protection (two stage, inverse time) ● Negative sequence over-current (two stage, inverse time) ● Reclose, etc ● Standard & Certificate: CE; IEC
Learn more

Acrel AM3SE-I Protection Relay

● A complete set of protection, related to the application ● 3 current input, 3 voltage input, 11DI, 5DO ● Auxiliary power supply adapts with AC220V, DC220V, DC110V, AC110V, DC48V, DC24V ● 1 RS485 serial communication, IEC60870-5-103 and Modbus-RTU ● 1 GPS for GPS timing ● More than 200 sequence of event records, more than 400 system logs, and more than 10 seconds tripping context records ● Powerful graphic programmable Logic ● Standard & Certificate: CE; IEC
Learn more

Acrel AM3SE-U Protection Relay

● A complete set of protection, related to the application ● 3 current input, 3 voltage input, 11DI, 5DO ● Auxiliary power supply adapts with AC220V, DC220V, DC110V, AC110V, DC48V, DC24V ● 1 RS485 serial communication, IEC60870-5-103 and Modbus-RTU ● 1 GPS for GPS timing ● More than 200 sequence of event records, more than 400 system logs, and more than 10 seconds tripping context records ● Powerful graphic programmable Logic ● Standard & Certificate: CE; IEC
Learn more

Acrel AM2SE-V Protection Relay

● A complete set of protection, related to the application; ● 4 current input, 3 voltage input, 8DI, 5DO; ● Auxiliary power supply adapts with AC220V, DC220V, DC110V, AC110V, DC48V, DC24V; ● 1 RS485 serial communication, IEC60870-5-103 and Modbus-RTU; ● more than 200 sequence of event records, more than 400 system logs, and more than 10 seconds tripping context records; ● Powerful graphic programmable Logic. ● Standard & Certificate: CE; IEC
Learn more

Acrel AM2SE-H Protection Relay

● A complete set of protection, related to the application; ● 4 current input, 3 voltage input, 8DI, 5DO; ● Auxiliary power supply adapts with AC220V, DC220V, DC110V, AC110V, DC48V, DC24V; ● 1 RS485 serial communication, IEC60870-5-103 and Modbus-RTU; ● more than 200 sequence of event records, more than 400 system logs, and more than 10 seconds tripping context records; ● Powerful graphic programmable Logic. ● Standard & Certificate: CE; IEC
Learn more

ABAT100-HS CE Approved Lead-acid Battery Monitoring Collector

● Display: Real-time data display, graphs, histogram display ● Historical Data: Query and export of equipment operation history, charging and discharging records and monitoring events ● Parameter Configuration: Provide basic information management functions ● Communication protocol: MODBUS-RTU ● Alarm mode: Local audible and visual alarm, indicator alarm, SMS alarm, etc. ● Capacity estimation: Group batteries SOC, SOH estimation; single battery SOC, SOH estimation ● Regular inspection: Intelligent judgment of the current state and automatic issuance of test commands ● Indicator light: Red and green LED lights, green light as the power light, red light as the indicator light
Learn more

ABAT100-C CE Approved Current Temperature Monitoring Module For Monitoring Lead-acid Battery

● High stability: Reliable and stable long-term operation ● Anti-jamming design: High anti-interference design, can block the ripple interference of high power high frequency UPS ● Communication protocol: MODBUS-RTU protocol ● Installation method: Tie-down mounting or adhesive mounting ● Indicator light: Red and green LED lights, green light as the power light, red light as the indicator light
Learn more

ABAT100-S-12 CE Approved Single Battery Monitoring Module For Monitoring 12V Lead-acid Battery

● Online monitoring: Online monitoring 24 hours a day, one battery per module, monitoring voltage, internal resistance and negative terminal temperature ● High accuracy measurement: Internal resistance ● Battery internal resistance test: Automatic periodic measurement of the internal resistance of each battery controlled by the collector ● Low power design: Manual entry into low power mode, S-module draws current from the battery down to 0.5mA ● Anti-jamming design: High anti-interference design, can block the ripple interference of high power high frequency UPS ● Communication protocol: MODBUS-RTU protocol ● Installation method: Tie-down mounting or adhesive mounting ● Indicator light: Red and green LED lights, green light as the power light, red light as the indicator light
Learn more
< 1...789...12 >